| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| atm.IfConnection-Set |
type=Children-Set |
| atm.IlmiLink-Set |
type=Children-Set |
| atm.PvcConnection-Set |
type=Children-Set |
| atm.VPConnection-Set |
type=Children-Set |
| atm.VTConnection-Set |
type=Children-Set |
| atmInterfaceCellFormat |
type=atm.ATMInterfaceCellFormat default=uni Displayed(tab/group)=ATM Interface Cell Format |
| atmInterfaceMapping |
tmnxATMIntfMapping OBJECT-TYPE
SYNTAX INTEGER <
direct (1),
plcp (2)
>
MAX-ACCESS read-write
STATUS current
DESCRIPTION"The value of tmnxATMIntfMapping specifies the cell
mapping that is to be used on this ATM interface. When
tmnxPortChanType does not have a value of 'pdhDs3 (14)',
'inconsistentValue' error will be returned to SNMP SET
requests. When tmnxPortChanType has a value of 'pdhDs3 (14)',
tmnxATMIntfMapping can be set to 'plcp (2)'."
type=atm.AtmInterfaceMapping default=direct Displayed(tab/group)=Interface Mapping |
| atmInterfaceMinimumVPIValue |
tmnxATMIntfMinVpValue OBJECT-TYPE
SYNTAX Integer32 (0..4095)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"tmnxATMIntfMinVpValue is used to set the minimum
allowable VPI value that can be used on the
ATM interface for a VPC."
DEFVAL < 0 >
::= < tmnxATMIntfEntry 2 >
type=int default=0 minimum=0 maximum=4095 Displayed(tab/group)=ATM Minimum VPI Value |
| connprof.ConnProfPolicy-Set |
type=Children-Set |
| interfaceAvailBWCells |
type=long access=read-only default=0 units=cells/sec Displayed(tab/group)=Available Bandwidth (Bandwidth/ATM Interface Bandwidth) |
| interfaceAvailableBandwidth |
type=long access=read-only default=0 units=bps Displayed(tab/group)=Available Bandwidth (Bandwidth/ATM Interface Bandwidth) |
| interfaceBufferPool |
The value of specifies the percentage of the buffers configured on this interface
over the maximum allowed on this interface.
type=int default=100 minimum=1 maximum=100 Displayed(tab/group)=Buffer Pool (/Buffer) |
| interfaceConfIfcs |
type=int access=read-only default=0 Displayed(tab/group)=In Use Interfaces |
| interfaceConfVccs |
type=int access=read-only default=0 Displayed(tab/group)=In Use VCCs |
| interfaceConfVpcs |
type=int access=read-only default=0 Displayed(tab/group)=In Use VPCs |
| interfaceConfVtcs |
type=int access=read-only default=0 Displayed(tab/group)=In Use VTCs |
| interfaceCurrentMaxVciBits |
type=int access=read-only default=16 Displayed(tab/group)=Current Max VCI Bits |
| interfaceCurrentMaxVpiBits |
type=int access=read-only default=8 Displayed(tab/group)=Current Max VPI Bits |
| interfaceCustomBufferMode |
The value of specifies whether port is in a mode that allows custom configuration of
port buffer pool and VC thresholds
type=boolean default=false Displayed(tab/group)=Buffer Mode (/Buffer) |
| interfaceEffectiveBandwidth |
type=long access=read-only default=0 units=bps |
| interfaceIlmiVci |
type=int access=read-only default=16 Displayed(tab/group)=ILMI VCI |
| interfaceIlmiVpi |
type=int access=read-only default=0 Displayed(tab/group)=ILMI VPI |
| interfaceMaxActiveVciBits |
type=int access=read-only default=16 Displayed(tab/group)=Max Active VCI Bits |
| interfaceMaxActiveVpiBits |
type=int access=read-only default=8 Displayed(tab/group)=Max Active VPI Bits |
| interfaceMaxVccs |
type=int access=read-only default=2000 Displayed(tab/group)=Max VCCs |
| interfaceMaxVpcs |
type=int access=read-only default=0 Displayed(tab/group)=Max VPCs |
| interfaceNominalBWCells |
type=long access=read-only default=0 units=cells/sec Displayed(tab/group)=Nominal Bandwidth (Bandwidth/ATM Interface Bandwidth) |
| interfaceNominalBandwidth |
type=long access=read-only default=0 units=bps Displayed(tab/group)=Nominal Bandwidth (Bandwidth/ATM Interface Bandwidth) |
| interfaceVcThreshold |
The value of specifies the VC buffer threshold for all VCs configured on this port
type=int default=190 minimum=190 maximum=117000 Displayed(tab/group)=VC Threshold (/Buffer) |
| mpr.PwAtmLayer-Set |
type=Children-Set |
| shelfId |
type=int access=read-only default=0 |
| snmpPortId |
type=long access=read-only default=0 |
| sonetequipment.VpShaping-Set |
type=Children-Set |
| tcAlarmState |
type=atm.TCAlarmState access=read-only Displayed(tab/group)=TC Alarm State (TC Sublayer) |
| totalBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Interface Total Bandwidth (Bandwidth) |
| totalEgressBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Egress Total Bandwidth (Bandwidth) |
| totalEgressCbrBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Egress CBR Bandwidth (Bandwidth) |
| totalEgressNrtVbrBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Egress NRT-VBR Bandwidth (Bandwidth) |
| totalEgressRtVbrBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Egress RT-VBR Bandwidth (Bandwidth) |
| totalEgressUbrBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Egress UBR Bandwidth (Bandwidth) |
| totalIngressBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Ingress Total Bandwidth (Bandwidth) |
| totalIngressCbrBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Ingress CBR Bandwidth (Bandwidth) |
| totalIngressNrtVbrBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Ingress NRT-VBR Bandwidth (Bandwidth) |
| totalIngressRtVbrBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Ingress RT-VBR Bandwidth (Bandwidth) |
| totalIngressUbrBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Ingress UBR Bandwidth (Bandwidth) |
| totalShapedBandwidth |
type=long access=read-only default=0 units=kbps Displayed(tab/group)=Interface Total Shaped Bandwidth (Bandwidth) |
| Properties inherited from netw.PortProtocolInterface |
|---|
| innerEncapValue, outerEncapValue, portPointer, terminationParticipationType |
| Properties inherited from netw.PortTerminatingInterface |
|---|
| innerEncapValue, outerEncapValue, portIdentifyingName, portPointer |
| Properties inherited from netw.StatefullConnectableInterface |
|---|
| administrativeState, compositeState, encapType, operationalState, resourceState, underlyingResourceState |
| Properties inherited from netw.LogicalInterface |
|---|
| application, description, displayedName, domain, nodeId, nodeName |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |
| Methods |
|---|
deployer
: Deployer - the deployment state
synchronousDeploy
: boolean - (Optional) Specify whether to block until the changes have been fully deployed to the network. A value of "true" means to block. A value of "false" means to return immediately. Default: false (asynchronous)
clearOnDeployFailure
: boolean - (Optional) Specify whether to clear any failed deployers. A value of "true" means to clear. A value of "false" means to leave the failed deployer. Default: false
deployRetries
: int - (Optional) The number of times to attempt re-deployment during synchronous deployment. This parameter is meaningless in the asynchronous case. Default: 0
deployRetryInterval
: long - (Optional) The number of milliseconds to wait between deployment retries. This parameter is meaningless in the asynchronous case. Default: 0
taskDescription
: string - (Optional) A user friendly description of what the operation does. This information will be used by the task manager.
instanceFullName
: string - the full name of the object.
interfaceConfigInfo
: config(atm.Interface) -
resultFilter
: ResultFilter - (Optional) Filter for narrowing down the information returned per object
continueOnFailure
: continueOnFailure - (Optional) Continue processing requests in this stream if an exception occurs, unless the request is invalid. Default: false
interfaceInfo
: summary(atm.Interface) -
atm.Interface.configureException
instanceFullName
: string - the full name of the object.
aInPortPointer
: string - The full name of the DS1E1Channel.
resultFilter
: ResultFilter - (Optional) Filter for narrowing down the information returned per object
continueOnFailure
: continueOnFailure - (Optional) Continue processing requests in this stream if an exception occurs, unless the request is invalid. Default: false
connProfInfoList
: List (summary(connprof.ConnProfPolicy)) -
atm.Interface.getAllConnectionProfileException
| Supported Network Elements | |
|---|---|
| 7750 SR | Supported until 23.3.R1 |
| 7705 SAR Gen 2 | |
| 7705 SAR | |
| 7450 ESS |
Supported from 8.0.R1 until 10.0.R1
|
| 7705 SAR H | Supported from 6.1.R1 |
| Product Specifics | |
| 7450 ESS 20.0 | |
| 7450 ESS 21.0 | |
| 7450 ESS 22.0 | |
| 7705 SAR H 20.0 | |
| 7705 SAR H 21.0 | |
| 7705 SAR H 22.0 | |
| 7705 SAR H 23.0 | |
| 7705 SAR H 24.0 | |
| 7705 SAR H 25.0 | |
| 7705 SAR H 9.0 | |
| 7705 SAR 20.0 | |
| 7705 SAR 21.0 | |
| 7705 SAR 22.0 | |
| 7705 SAR 23.0 | |
| 7705 SAR 24.0 | |
| 7705 SAR 25.0 | |
| 7750 SR 20.0 | |
| 7750 SR 21.0 | |
| 7750 SR 22.0 | |