| Properties | |
|---|---|
| description |
Specifies the description of the service endpoint
type=string default= minimum=0 maximum=80 Displayed(tab/group)=Description |
| displayedName |
Specifies the name of the service endpoint
type=string access=read-create default= minimum=1 maximum=32 Mandatory on create Displayed(tab/group)=Name |
| forceSwitchOver |
Specifies whether to force a switchover of the active SDP binding.
When it is set to 'doAction', the SDP binding specified by
switchOverSdpBindingPointer will become active.
type=service.ForceSwitchOverAction default=notApplicable |
| lastResynced |
This indicates last time NFM-P fetched the "active up time" and
"revert time count down" from the router. Those two properties
can potentially change and NFM-P will not automatically resync the
value every time they change.
type=Date access=read-only default=0 Displayed(tab/group)=Last Resync Time (/Active Up Time and Revert Time Count Down) |
| operationalFlags |
Aggregated operational flags state of the endpoint calculated from the states of
its SDP Bindings and SAPs.
type=service.EndpointOperFlags access=read-only default=0 Displayed(tab/group)=Operational Flags |
| revertTime |
Specifies the time to wait before reverting back to the primary
spoke-sdp defined on this service endpoint, after having
failed over to a backup spoke-sdp
type=int minimum=-1 maximum=600 units=seconds Displayed(tab/group)=Revert Time |
| revertTimeCountDown |
Indicates the timer count down before reverting back to the
primary spoke SDP binding defined on this service end point, after
having failed over to a backup spoke SDP binding. This timer count
down begins after primary Spoke SDP becomes operational.
The value of -1 indicates when revert is not applicable.
type=int access=read-only minimum=-1 maximum=600 Displayed(tab/group)=Revert Time Count Down (/Active Up Time and Revert Time Count Down) |
| serviceId |
type=long access=read-only default=0 Displayed(tab/group)=Service ID |
| serviceName |
type=string access=read-only default= maximum=64 |
| siteId |
type=string access=read-only default=0.0.0.0 maximum=50 Displayed(tab/group)=Site ID |
| svcComponentId |
type=long access=read-only default=0 |
| switchOverSdpBindingPathId |
Specifies the path id of the Spoke SDP binding on this endpoint
which is switched to.
type=long default=0 |
| switchOverSdpBindingVcId |
Specifies the vc id of the Spoke SDP binding on this endpoint
which is switched to.
type=long default=0 |
| switchOverSdpFecId |
Specifies the fec id of the Spoke SDP FEC on this endpoint
which is switched to.
type=long default=0 |
| txActiveChangeCount |
Indicates the number of times active transmit change has taken
place in this end point.
type=long access=read-only default=0 Displayed(tab/group)=Active Change Count |
| txActiveEncapValue |
Specifies the combined encapsulation value of the SAP that is transmit active.
This object is only valid when txActiveType is sap(1). Internal use only.
type=long access=read-only default=0 |
| txActiveLastChange |
Indicates the value of sysUpTime at the time of the last active
transmit change in this end point.
type=Date access=read-only default=0 Displayed(tab/group)=Active Last Change Time |
| txActivePortId |
Specifies the Port Id of the SAP that is transmit active.
This object is only valid when txActiveType is sap(1). Internal use only.
type=long access=read-only default=0 |
| txActiveSapPointer |
The pointer pointing to the transmit active SAP.
type=Pointer access=read-only default= |
| txActiveSdpBindingPathId |
Specifies the pathId of the active Spoke SDP binding.
This object is only valid when txActiveType is sdpBinding(2).
type=long access=read-only default=0 |
| txActiveSdpBindingPointer |
The pointer pointing to the transmit active Spoke SDP binding.
type=Pointer access=read-only default= |
| txActiveSdpBindingVcId |
Specifies the vcId of the Active Spoke SDP binding.
This object is only valid when txActiveType is sdpBinding(2).
type=long access=read-only default=0 |
| txActiveSdpFecPointer |
The pointer pointing to the transmit active Spoke SDP FEC.
type=Pointer access=read-only default= |
| txActiveType |
Specifies the type of endpoint object that is current transmit active
type=service.TxActiveType access=read-only default=none Displayed(tab/group)=Active Object |
| txActiveUpTime |
Indicates the active 'up' time (in hundredths of a second)
of the end-point object that is current transmit active.
type=Time access=read-only default=0 Displayed(tab/group)=Active Up Time (/Active Up Time and Revert Time Count Down) |
| Properties inherited from ManagedObject |
|---|