| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| aptsAsymmetryCompensation |
type=boolean default=false Displayed(tab/group)=APTS Asymmetry Compensation |
| clockAccuracy |
type=int access=read-only Displayed(tab/group)=Accuracy, Clock Accuracy (/Default Data Set Attributes), Clock Accuracy (PTP Clock/Default Data Set Attributes) |
| clockAddress |
type=InetAddress access=read-only default=0.0.0.0 Displayed(tab/group)=Parent Clock Address (/Parent Clock) |
| clockAdminFreqSource |
Specifies the configured setting for the source of the PTP clock.
A reboot of the NE may be required for the configured value to take effect.
See the NE documentation for more information.
type=ptp.PtpClockAdminFreqSource default=0 Displayed(tab/group)=Frequency Source |
| clockAdminState |
type=ptp.AluPtpClockAdminState default=3 Displayed(tab/group)=Admin State, Admin State (PTP Clock/Default Data Set Attributes) |
| clockAlarmProfileName |
>
Specifies the ASAP (alarm severity assignment profile) Name for PTP clock.
DEPRECATED: 23.4 - No longer applicable to any supported nodes type=Pointer access=read-only |
| clockClass |
type=int access=read-only Displayed(tab/group)=Clock Class, Clock Class (/Default Data Set Attributes), Clock Class (PTP Clock/Default Data Set Attributes) |
| clockDomain |
type=long default=0 minimum=0 maximum=255 Displayed(tab/group)=Domain, Domain (PTP Clock/Default Data Set Attributes) |
| clockDynamicPeers |
type=boolean default=false Displayed(tab/group)=Dynamic Peers |
| clockEnabled |
type=ptp.PtpClockEnabled Displayed(tab/group)=Clock Enabled (/Default Data Set Attributes) |
| clockEthernetPort |
type=string access=read-only Displayed(tab/group)=Parent Clock Ethernet Port (/Parent Clock) |
| clockForwardWeight |
type=int access=read-only Displayed(tab/group)=Forward Weight |
| clockGMAccuracy |
type=long access=read-only Displayed(tab/group)=GM Clock Accuracy (/Parent Clock), Grandmaster Clock Accuracy (/Parent Clock Data Set Attributes), Grandmaster Clock Accuracy (PTP Clock/Parent Clock Data Set Attributes) |
| clockGMClass |
type=long access=read-only units=sec Displayed(tab/group)=GM Clock Class (/Parent Clock), Grandmaster Clock Class (/Parent Clock Data Set Attributes), Grandmaster Clock Class (PTP Clock/Parent Clock Data Set Attributes) |
| clockGMClockId |
type=string access=read-only Displayed(tab/group)=GM Clock Id (/Parent Clock), Grandmaster Clock ID (/Parent Clock Data Set Attributes), Grandmaster Clock ID (PTP Clock/Parent Clock Data Set Attributes) |
| clockGMPriority1 |
type=long access=read-only Displayed(tab/group)=GM Clock Priority1 (/Parent Clock), Grandmaster Priority 1 (/Parent Clock Data Set Attributes), Grandmaster Priority 1 (PTP Clock/Parent Clock Data Set Attributes) |
| clockGMPriority2 |
type=long access=read-only Displayed(tab/group)=GM Clock Priority2 (/Parent Clock), Grandmaster Priority 2 (/Parent Clock Data Set Attributes), Grandmaster Priority 2 (PTP Clock/Parent Clock Data Set Attributes) |
| clockGMVariance |
type=long access=read-only Displayed(tab/group)=GM Clock Variance (/Parent Clock), Grandmaster Offset Scaled Log Variance (/Parent Clock Data Set Attributes), Grandmaster Offset Scaled Log Variance (PTP Clock/Parent Clock Data Set Attributes) |
| clockHw |
type=long access=read-only default=0 |
| clockHwPointer |
type=Pointer default= Displayed(tab/group)=Clock MDA |
| clockId |
Specifies IEEE 1588 PTP clock.
type=int access=read-create minimum=1 maximum=16 Mandatory on create Displayed(tab/group)=Clock Index, Clock Index (PTP Clock/Default Data Set Attributes) |
| clockInterfaceName |
type=string access=read-only default= maximum=252 |
| clockInterfacePointer |
type=Pointer default= Displayed(tab/group)=Source Interface |
| clockIpAddrType |
type=rtr.InetAddressType access=read-only default=ipv4 Displayed(tab/group)=Parent Clock Address Type (/Parent Clock) |
| clockLocalPriority |
Specifies the value that the clock uses to select a timing source, when the PTP algorithm produces a tie for best master clock.
type=int default=128 minimum=1 maximum=255 Displayed(tab/group)=Clock Local Priority, Local Priority (PTP Clock/Default Data Set Attributes) |
| clockMacAddress |
type=MacAddress access=read-only default=00-00-00-00-00-00 Displayed(tab/group)=Parent Clock MacAddress (/Parent Clock) |
| clockMode |
Specifies the PTP Clock Mode
type=ptp.PtpClockMode default=0 Displayed(tab/group)=Clock Mode (PTP Clock) |
| clockMulticastAddress |
type=ptp.PTPPortMulticastAddress default=1 Displayed(tab/group)=Multicast MAC |
| clockNetworkPdv |
type=ptp.Alu1588PtpClockNetworkPdv default=1 Displayed(tab/group)=Network PDV |
| clockNetworkType |
type=ptp.PtpClockNetworkType default=2 Displayed(tab/group)=Network Type |
| clockNumberPorts |
type=int access=read-only Displayed(tab/group)=Number of Ports, Number of PTP Ports (/Default Data Set Attributes), Number of PTP Ports (PTP Clock/Default Data Set Attributes) |
| clockOperFreqSource |
Specifies the currently effective setting for the source of the PTP clock.
type=ptp.PtpClockAdminFreqSource access=read-only Displayed(tab/group)=Oper Frequency Source |
| clockParentId |
type=string access=read-only Displayed(tab/group)=Parent Clock ID (/Parent Clock), Clock ID (/Parent Clock Data Set Attributes), Clock ID (PTP Clock/Parent Clock Data Set Attributes) |
| clockParentPortNumber |
type=long access=read-only Displayed(tab/group)=Parent Port Number (/Parent Clock), PTP Port (/Parent Clock Data Set Attributes), PTP Port number (PTP Clock/Parent Clock Data Set Attributes) |
| clockPortName |
Indicates the port of the parent clock. This port is an Ethernet port or a GNSS port .
If there is no parent clock, or the parent clock is not reachable via a port,port shows Empty value.
type=string access=read-only Displayed(tab/group)=Port (/Parent Clock) |
| clockPrimaryDomain |
It specifies the domain number of the primary syntonization domain.
type=int default=24 minimum=24 maximum=43 Displayed(tab/group)=Primary Domain (PTP Clock/Default Data Set Attributes) |
| clockPriority1 |
type=long default=128 minimum=0 maximum=255 Displayed(tab/group)=Clock Priority 1, Priority 1 (/Default Data Set Attributes), Priority 1 (PTP Clock/Default Data Set Attributes) |
| clockPriority2 |
type=long default=128 minimum=0 maximum=255 Displayed(tab/group)=Clock Priority 2, Priority 2 (/Default Data Set Attributes), Priority 2 (PTP Clock/Default Data Set Attributes) |
| clockProfile |
Specifies the standard that defines the PTP features allowed on a device.
type=ptp.Alu1588PtpProfile default=2 Displayed(tab/group)=PTP Profile |
| clockRecoveryState |
type=ptp.Alu1588PtpPortRecoveredClockState access=read-only Displayed(tab/group)=Clock Synchronization State, Clock State (/Current Data Set Attributes), Clock State (PTP Clock/Current Data Set Attributes) |
| clockReverseWeight |
type=int access=read-only Displayed(tab/group)=Reverse Weight |
| clockSlave |
type=boolean default=true Displayed(tab/group)=Clock Slave Only |
| clockTimeRecState |
The state of the Time Recovery.
type=ptp.PtpClockTimeRecoveryState access=read-only Displayed(tab/group)=Time Recovery State, Clock Time Recovery State |
| clockTimeRefPriority |
type=long default=0 minimum=0 maximum=16 Displayed(tab/group)=Clock Time Reference Priority |
| clockTransportProtocol |
type=ptp.Alu1588PtpClockTransportProtocol default=1 Displayed(tab/group)=Transport Protocol |
| clockTransportType |
type=ptp.PtpTransportType access=read-only Displayed(tab/group)=Parent Clock Transport Type (/Parent Clock) |
| clockTwoStepType |
type=ptp.Alu1588PtpClockStepType access=read-only Displayed(tab/group)=Two Step |
| clockType |
type=ptp.Alu1588PtpClockType default=2 Displayed(tab/group)=Clock Type |
| clockVariance |
type=long access=read-only Displayed(tab/group)=Clock Variance, Offset Scaled Log Variance (/Default Data Set Attributes), Offset Scaled Log Variance (PTP Clock/Default Data Set Attributes) |
| csmClockUseNodeTime |
type=boolean access=read-only default=false Displayed(tab/group)=Use Node Time |
| currentTime |
type=string access=read-only units=UTC Displayed(tab/group)=Current Time (/Current Data Set Attributes), Current Time (/Time Information), Current Time (PTP Clock/Current Data Set Attributes) |
| currentUTCOffset |
type=int access=read-only units=seconds Displayed(tab/group)=Current UTC Offset (/Time Information), Current UTC Offset (PTP Clock/Time Information) |
| currentUtcOffsetValid |
type=ptp.PtpClockAttributesTriState access=read-only Displayed(tab/group)=Current UTC Offset Valid (/Time Information), Current UTC Offset Valid (PTP Clock/Time Information) |
| delayLossDetectionInterval |
It gives the number of DELAY_RESP Interval to raise PtpClock DELAYRESPLOSS alarm.
type=int default=3 minimum=2 maximum=255 Displayed(tab/group)=Detection Time of delayResLoss Alarm (PTP Clock/Clock Sync OAM Information) |
| eprtcSupport |
It is used to Enable/Disable the Enhanced Primary Reference Time Clock.
type=boolean default=false |
| frequencyTraceable |
type=ptp.PtpClockAttributesTriState access=read-only Displayed(tab/group)=Frequency Traceable (/Time Information), Frequency Traceable (PTP Clock/Time Information) |
| leap59 |
type=ptp.PtpClockAttributesTriState access=read-only Displayed(tab/group)=Leap 59 (/Time Information), Leap 59 (PTP Clock/Time Information) |
| leap61 |
type=ptp.PtpClockAttributesTriState access=read-only Displayed(tab/group)=Leap 61 (/Time Information), Leap 61 (PTP Clock/Time Information) |
| localPtpPeerIndex |
The Local PTP Peer Index value indicates an index for an entry in
the PTP master table that is associated with the current master
clock.
type=int access=read-only minimum=0 maximum=50 Displayed(tab/group)=Local PTP Peer Index (/Parent Clock) |
| localPtpPortIndex |
The Local PTP Port Index value indicates an index for an entry in
the PTP master table that is associated with the current master
clock.
type=int access=read-only minimum=0 maximum=50 Displayed(tab/group)=Local PTP Port Index (/Parent Clock) |
| lockedPtpPort |
type=int access=read-only Displayed(tab/group)=Locked PTP Port (/Current Data Set Attributes), Locked PTP Port (PTP Clock/Current Data Set Attributes) |
| logDelayInterval |
type=long default=0 minimum=-6 maximum=0 Displayed(tab/group)=Log delay interval |
| logSyncInterval |
Specifies the packet request rate for clock synchronization packets from the master clock.
A value of -3 = 8 packets per second (pps), -4 = 16 pps, -5 = 32 pps, and -6 = 64 pps.
The -6 option is recommended when PTP is selected as the first timing reference.
type=long default=-6 minimum=-6 maximum=0 Displayed(tab/group)=Log sync interval |
| maxStepsRemoved |
type=int default=255 minimum=1 maximum=255 Displayed(tab/group)=Max Steps Removed (PTP Clock/Default Data Set Attributes) |
| meanPathDelay |
type=int access=read-only units=ns Displayed(tab/group)=Mean Path Delay (/Current Data Set Attributes), Mean Path Delay (PTP Clock/Current Data Set Attributes) |
| offsetFromMaster |
type=int access=read-only units=ns Displayed(tab/group)=Offset From Master (/Current Data Set Attributes), Offset From Master (PTP Clock/Current Data Set Attributes) |
| offsetScaledLogVariance |
type=int access=read-only Displayed(tab/group)=Offset Scaled Log Variance (/Parent Clock Data Set Attributes), Offset Scaled Log Variance (PTP Clock/Parent Clock Data Set Attributes) |
| parentClockSyncUncertain |
This specifies whether the master clock is reporting Sync Uncertain or not.
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Clock Sync Uncertain (/Parent Clock) |
| parentSyncCertaintyState |
type=ptp.SyncCertaintyState access=read-only default=unknown Displayed(tab/group)=Rx Sync Certainty (/Parent Clock) |
| pathTraceEnable |
It enables/disables the path trace mechanism.
type=boolean default=false Displayed(tab/group)=Path Trace Enable (PTP Clock/Path Trace Information) |
| pathTraceList |
It gives a list of clock identity values.
type=string access=read-only Displayed(tab/group)=Path Trace List (PTP Clock/Path Trace Information) |
| peerLimit |
Specifies the maximum number of PTP peers that may be created by the system upon reception of PTP signaling packets.
If the system has already automatically created PTP peers on a virtualrouter instance, the limit cannot be reduced lower than the current
count of automatically created PTP peers on the virtual router instance.
type=int default=-1 minimum=-1 maximum=512 Displayed(tab/group)=Peer Limit |
| phaseChangeRate |
type=int access=read-only Displayed(tab/group)=Phase Change Rate (/Parent Clock Data Set Attributes), Phase Change Rate (PTP Clock/Parent Clock Data Set Attributes) |
| ptp.IEEEPTPAlternateProfile-Set |
type=Children-Set |
| ptp.IEEEPTPAlternateProfileInterWorking-Set |
type=Children-Set |
| ptp.IEEEPTPCPMClock-Set |
type=Children-Set |
| ptp.IEEEPTPGNSSPort-Set |
type=Children-Set |
| ptp.IEEEPTPPeer-Set |
type=Children-Set |
| ptp.IEEEPTPPort-Set |
type=Children-Set |
| ptpClockAnnoRxTimeout |
type=int default=3 minimum=2 maximum=10 Displayed(tab/group)=Clock Announce Rx Timeout |
| ptpClockAnnounceInterval |
Specifies the packet rate requested in REQUEST_UNICAST_TRANSMISSION signaling messages for announce packets.
type=int default=1 minimum=-3 maximum=4 units=log base 2 seconds Displayed(tab/group)=Clock Announce Interval |
| ptpClockId |
type=string access=read-only Displayed(tab/group)=Clock ID, Clock ID (/Default Data Set Attributes), Clock ID (PTP Clock/Default Data Set Attributes) |
| ptpInputDegradeThreshold |
It gives the threshold value to raise PtpClock PTPINPUTDEG alarm.
type=int default=6 minimum=6 maximum=248 Displayed(tab/group)=Threshold value for ptpInputDeg Alarm (PTP Clock/Clock Sync OAM Information) |
| ptpStepsRemoved |
type=int access=read-only Displayed(tab/group)=PTP Steps Removed |
| ptpTimeInaccuracyOverride |
type=long default=0 minimum=0 maximum=10000000 units=ns Displayed(tab/group)=Time Inaccuracy Override |
| ptpTimeInfoCurrentUtcOffset |
The value of ptpTimeInfoCurrentUtcOffset indicates the offset between International Atomic Time (TAI) and Coordinated Universal Time(UTC), in seconds.
type=int access=read-only default=0 units=seconds Displayed(tab/group)=Current UTC Offset (/Time Information) |
| ptpTimeInfoLastAdjustment |
The value of ptpTimeInfoLastAdjustment indicates the last
adjustment in nanoseconds to the local time of the PTP clock
type=string access=read-only units=ns Displayed(tab/group)=Last Adjustment (/Time Recovery) |
| ptpTimeInfoLastCalc |
The value of ptpTimeInfoLastCalc indicates the time, since system startup, when ptpTimeInfoOffsetFromMaster and
ptpTimeInfoMeanPathDelay were last calculated.
type=Date access=read-only default=0 Displayed(tab/group)=Last Adjustment/Offset/MeanPath Last Calculated (/Time Recovery) |
| ptpTimeInfoLeap59 |
The value of ptpTimeInfoLeap59 indicates whether the last minute of the current UTC day contains 59 seconds.
type=boolean access=read-only default=false Displayed(tab/group)=Leap 59 Second (/Time Information) |
| ptpTimeInfoLeap61 |
The value of ptpTimeInfoLeap61 indicates whether the last minute of the current UTC day contains 61 seconds.
type=boolean access=read-only default=false Displayed(tab/group)=Leap 61 Second (/Time Information) |
| ptpTimeInfoMeanPathDelay |
The value of ptpTimeInfoMeanPathDelay indicates the current value of the mean propagation time between the local PTP clock and the
parent PTP clock, calculated by the local clock, as per IEEE Std 1588-2008.
type=string access=read-only units=ns Displayed(tab/group)=Mean Path Delay (/Time Recovery) |
| ptpTimeInfoOffsetFromMaster |
The value of ptpTimeInfoOffsetFromMaster indicates the current offset of the local PTP clock from the parent PTP clock,
calculated by the local clock, as per IEEE Std 1588-2008.
type=string access=read-only units=ns Displayed(tab/group)=Offset From Master (/Time Recovery) |
| ptpTimeInfoUtcOffsetValid |
The value of ptpTimeInfoUtcOffsetValid indicates whether the offset indicated by ptpTimeInfoCurrentUtcOffset is known to be correct.
type=boolean access=read-only default=false Displayed(tab/group)=UTC Offset Valid (/Time Information) |
| ptpTimeScale |
type=ptp.PtpTimescale access=read-only Displayed(tab/group)=PTP Timescale (/Time Information), PTP Timescale (PTP Clock/Time Information) |
| ptpTimeSource |
type=ptp.PtpTimesource access=read-only Displayed(tab/group)=PTP Time Source (/Time Information), PTP Time Source (PTP Clock/Time Information) |
| ptsfUnusabAdminState |
type=ptp.PtpPtsfUnusableAdminState default=3 Displayed(tab/group)=PTSF Unusable Admin State |
| realtimeTimeOffset1 |
It gives the PTP Clock Realtime Time Offset part 1.
type=string access=read-only |
| realtimeTimeOffset2 |
It gives the PTP Clock Realtime Time Offset part 2.
type=string access=read-only |
| realtimeTimeOffset3 |
It gives the PTP Clock Realtime Time Offset part 3.
type=string access=read-only |
| realtimeTimeOffsetDuration |
It gives the Duration time (in minutes) for the PTP Clock Realtime Time Offset.
type=int default=1 minimum=1 maximum=15 units=minutes Displayed(tab/group)=Realtime Time Offset Duration (PTP Clock/Clock Sync OAM Information) |
| realtimeTimeOffsetInterval |
It gives the Interval time (in seconds) for the PTP Clock Realtime Time Offset.
type=int default=5 minimum=1 maximum=5 units=seconds Displayed(tab/group)=Realtime Time Offset Interval (PTP Clock/Clock Sync OAM Information) |
| siteId |
type=string access=read-only default=0.0.0.0 maximum=50 Displayed(tab/group)=Site ID, Site ID (PTP Clock) |
| statisticsCollected |
type=boolean access=read-only Displayed(tab/group)=Statistics Collected (/Parent Clock Data Set Attributes), Statistics Collected (PTP Clock/Parent Clock Data Set Attributes) |
| stepsRemoved |
type=int access=read-only Displayed(tab/group)=Steps Removed (/Current Data Set Attributes), Steps Removed (PTP Clock/Current Data Set Attributes) |
| syncCertaintyState |
It indicates the synchronization certainty state of the clock.
type=ptp.SyncCertaintyState access=read-only default=unknown Displayed(tab/group)=Sync Certainty State |
| syncLossDetectionInterval |
It specifies the number of SYNC Interval to raise PtpClock SYNCLOSS alarm.
type=int default=3 minimum=2 maximum=255 Displayed(tab/group)=Detection Time of syncLoss Alarm (PTP Clock/Clock Sync OAM Information) |
| syncUncertain |
This specifies synchronization uncertain indication of the local PTP clock
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Sync Uncertain |
| syncUncertainFlag |
It indicates if the Synchronization Uncertain flag of incoming announce message
from the parent clock is TRUE or FALSE.
type=boolean access=read-only Displayed(tab/group)=Synchronization Uncertain flag (PTP Clock/Time Information) |
| syncUncertainMonitoring |
It specifies the Enable/Disable Synchronization Uncertain Indication Monitoring.
type=boolean default=false Displayed(tab/group)=Synchronization Uncertain Indication Monitoring (PTP Clock/Default Data Set Attributes) |
| syncUncertainReason |
This specifies why syncUncertain is set to TRUE
type=ptp.SyncUncertainReason access=read-only Displayed(tab/group)=Sync Uncertain Reason |
| timeErrorReferencePortIndex |
It gives the Reference Input 1PPS/ToD port index for the PTP Time Error(PTERREF).
type=int default=0 minimum=0 maximum=2147483647 Displayed(tab/group)=Time Error Reference Port Index (PTP Clock/Clock Sync OAM Information) |
| timeTraceable |
type=ptp.PtpClockAttributesTriState access=read-only Displayed(tab/group)=Time Traceable (/Time Information), Time Traceable (PTP Clock/Time Information) |
| twoStepFlag |
type=ptp.PtpClockAttributesTriState access=read-only Displayed(tab/group)=Two-Step Flag (/Default Data Set Attributes), Two-Step Flag (PTP Clock/Default Data Set Attributes) |
| txWhileSyncUncertain |
This specifies whether the PTP clock will transmit packets on PTP ports in the master state, even
if the local clock is uncertain that it is synchronized to a valid timing source.
type=generic.TruthValue default=false Displayed(tab/group)=Tx While Sync Uncertain |
| txWhileUncertain |
type=boolean default=true Displayed(tab/group)=Tx While UnCertain |
| useNodeTime |
type=boolean default=false Displayed(tab/group)=Use Node Time |
| waitToRestore |
Specifies the time to wait after an Announce Receipt Timeout expires before considering
further announce messages from a peer for the purposes of selecting a master clock.
type=int default=0 minimum=0 maximum=600 Displayed(tab/group)=Wait To Restore |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |