| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| availabilityStatus |
Indicates the availability of the read-only data
of the current row.
type=vwm.VwmMsInventoryStatus access=read-only Displayed(tab/group)=Availability Status (OPS OSM Protection Switch/OPS OSM Specifics) |
| bounceTimer |
Protection switch bounce timer.
type=long minimum=0 maximum=65535 units=ms Displayed(tab/group)=Bounce Timer (OPS OSM Protection Switch/OPS OSM Specifics) |
| description |
Description of the OSM protection switch instance.
type=string default= maximum=64 Displayed(tab/group)=Description (OPS OSM Protection Switch/OPS OSM Specifics) |
| evaluationTimer |
Protection switch evaluation timer.
type=long minimum=0 maximum=65535 units=ms Displayed(tab/group)=Evaluation Timer (OPS OSM Protection Switch/OPS OSM Specifics) |
| externalCommand |
Protection switch external command status.
type=string access=read-only Displayed(tab/group)=External Command (OPS OSM Protection Switch/OPS OSM Specifics) |
| holdOffTimer |
Protection switch hold-off timer.
type=long default=1 minimum=1 maximum=65535 units=ms Displayed(tab/group)=Hold Off Timer (OPS OSM Protection Switch/OPS OSM Specifics) |
| maxSwitchCount |
Maximum number of switch counts.
type=long minimum=0 maximum=65535 Displayed(tab/group)=Max Switch Count (OPS OSM Protection Switch/OPS OSM Specifics) |
| osmDsvactualSelectorPosition |
"The actual position of the PMU-D BAND selector."
type=vwm.OpsOsmDsvSelectorPosition access=read-only Displayed(tab/group)=Actual Selector Position (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvapsActive |
"Indicates whether automatic protection switching
is active for this OSM-DSV."
type=generic.TruthValue access=read-only Displayed(tab/group)=Aps Active (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvconfigSelectorPosition |
"The actual position of the PMU-D BAND selector."
type=vwm.OpsOsmDsvSelectorPosition Displayed(tab/group)=Configured Selector Position (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsveVoaSigIn |
"Actual attenuation value of the eVOA in the SIG IN port."
type=float access=read-only Displayed(tab/group)=E Voa Sig In (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsveVoaSigInAOut |
"Attenuation value of the eVOA in the SIG IN port in case the TX selector points to the A OUT port."
type=float minimum=0 maximum=15 units=dB Displayed(tab/group)=E Voa Sig In A Out (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsveVoaSigInBOut |
"Attenuation value of the eVOA in the SIG IN port in case the TX selector points to the B OUT port."
type=float minimum=0 maximum=15 units=dB Displayed(tab/group)=E Voa Sig In B Out (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsveVoaSigOut |
"Actual attenuation value of the eVOA in the SIG OUT port."
type=float access=read-only Displayed(tab/group)=E Voa Sig Out (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsveVoaSigOutAIn |
"Attenuation value of the eVOA in the SIG OUT port in case the RX selector points to the A IN port."
type=float minimum=0 maximum=15 units=dB Displayed(tab/group)=E Voa Sig Out A In (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsveVoaSigOutBIn |
"Attenuation value of the eVOA in the SIG OUT port in case the RX selector points to the B IN port."
type=float minimum=0 maximum=15 units=dB Displayed(tab/group)=E Voa Sig Out B In (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvoprA |
"Optical Power Received (OPR) defect status of port A."
type=generic.TruthValue access=read-only Displayed(tab/group)=OPR A (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvoprB |
"Optical Power Received (OPR) defect status of port B."
type=generic.TruthValue access=read-only Displayed(tab/group)=OPR B (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvoprSIG |
"Optical Power Received (OPR) defect status of port SIG."
type=generic.TruthValue access=read-only Displayed(tab/group)=OPR SIG (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvopsOsmDsvAvailabilityStatus |
Indicates the availability of the following read-only
data of the current row :
- tnVwmMsOpsOsmDsvRxPowerA
- tnVwmMsOpsOsmDsvRxPowerB
- tnVwmMsOpsOsmDsvRxPowerSIG
- tnVwmMsOpsOsmDsvTxPowerSIG
- tnVwmMsOpsOsmDsvEVoaSigIn
- tnVwmMsOpsOsmDsvEVoaSigOut
type=vwm.VwmMsInventoryStatus access=read-only Displayed(tab/group)=Availability Status (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvrxPowerA |
"Power of input signal of port A."
type=float access=read-only Displayed(tab/group)=Rx Power A (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvrxPowerB |
"Power of input signal of port B."
type=float access=read-only Displayed(tab/group)=Rx Power B (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvrxPowerSIG |
"Power of input signal of port SIG."
type=float access=read-only Displayed(tab/group)=Rx Power SIG (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvthresholdA |
Power threshold for the input signal of port A.
type=float default=-27.0 minimum=-30 maximum=35 units=dBm Displayed(tab/group)=Threshold A (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvthresholdB |
Power threshold for the input signal of port B.
type=float default=-27.0 minimum=-30 maximum=35 units=dBm Displayed(tab/group)=Threshold B (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvthresholdHysteresis |
Power Hysteresis for input signals.
type=float default=1.0 minimum=1 maximum=3 units=dB Displayed(tab/group)=Threshold Hysteresis (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvthresholdSigIn |
Power threshold for the input signal of port SIG.
type=float default=-27.0 minimum=-30 maximum=35 units=dBm Displayed(tab/group)=Threshold Sig In (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvthresholdSigOut |
Power threshold for the output signal of port SIG.
type=float default=-27.0 minimum=-30 maximum=35 units=dBm Displayed(tab/group)=Threshold Sig Out (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| osmDsvtxPowerSIG |
"Power of output signal of port SIG."
type=float access=read-only Displayed(tab/group)=Tx Power SIG (OPS OSM Protection Switch/OPS OSM-DSV Specifics) |
| powerA |
Power of input signal of port A.
type=float access=read-only units=dBm Displayed(tab/group)=Receive Power A (OPS OSM Protection Switch/OPS OSM Specifics) |
| powerB |
Power of input signal of port B.
type=float access=read-only units=dBm Displayed(tab/group)=Receive Power B (OPS OSM Protection Switch/OPS OSM Specifics) |
| powerSIG |
Power of input signal of port SIG.
type=float access=read-only units=dBm Displayed(tab/group)=Receive Power SIG (OPS OSM Protection Switch/OPS OSM Specifics) |
| resetSwitchCount |
Reset Switch Count
type=generic.TruthValue Displayed(tab/group)=Reset Switch Count (OPS OSM Protection Switch/OPS OSM Specifics) |
| rxPos |
RX selector position.
type=string access=read-only Displayed(tab/group)=RX selector position (OPS OSM Protection Switch/OPS OSM Specifics) |
| shelfId |
shelf identifier
type=int default=1 minimum=1 maximum=2047 |
| slotId |
slot identifier
type=int default=1 minimum=1 maximum=255 |
| state |
Protection switch status.
type=string access=read-only Displayed(tab/group)=Switch Status (OPS OSM Protection Switch/OPS OSM Specifics) |
| switchCommand |
User configurable protection switch command.
type=vwm.OpsOsmSwitchCommand Displayed(tab/group)=Switch Command (OPS OSM Protection Switch/OPS OSM Specifics) |
| switchCount |
Actual number of switch counts.
type=long access=read-only minimum=0 maximum=4294967295 Displayed(tab/group)=Switch Count (OPS OSM Protection Switch/OPS OSM Specifics) |
| switchCountResetTimer |
Protection switch count reset timer.
type=long minimum=0 maximum=4294967295 units=ms Displayed(tab/group)=Switch Count Reset Timer (OPS OSM Protection Switch/OPS OSM Specifics) |
| thresholdA |
Power threshold for the input signal of port A.
type=float minimum=-30 maximum=35 units=dBm Displayed(tab/group)=Threshold A (OPS OSM Protection Switch/OPS OSM Specifics) |
| thresholdB |
Power threshold for the input signal of port B.
type=float minimum=-30 maximum=35 units=dBm Displayed(tab/group)=Threshold B (OPS OSM Protection Switch/OPS OSM Specifics) |
| thresholdHysteresis |
Power Hysteresis for input signals.
type=float default=1.0 minimum=1 maximum=3 units=dB Displayed(tab/group)=Threshold Hysteresis (OPS OSM Protection Switch/OPS OSM Specifics) |
| thresholdSIG |
Power threshold for the input signal of port SIG.
type=float minimum=-30 maximum=35 units=dBm Displayed(tab/group)=Threshold SIG (OPS OSM Protection Switch/OPS OSM Specifics) |
| txPos |
TX selector position.
type=string access=read-only Displayed(tab/group)=TX selector position (OPS OSM Protection Switch/OPS OSM Specifics) |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |
| Supported Network Elements | |
|---|---|
| 1830 VWM OSU | Supported from 8.3.0 |
| Product Specifics | |
| 1830 VWM OSU 8.3 | |
| 1830 VWM OSU 8.4 | |
| 1830 VWM OSU 8.5 | |
| 1830 VWM OSU 9.0 | |