vwm
OpsOsmProtectionSwitch



public class OpsOsmProtectionSwitch

Properties
availabilityStatus Indicates the availability of the read-only data of the current row.

type=vwm.VwmMsInventoryStatus
access=read-only
Displayed(tab/group)=Availability Status (OPS OSM Protection Switch/OPS OSM Specifics)

bounceTimer Protection switch bounce timer.

type=long
minimum=0
maximum=65535
units=ms
Displayed(tab/group)=Bounce Timer (OPS OSM Protection Switch/OPS OSM Specifics)

description Description of the OSM protection switch instance.

type=string
default=
maximum=64
Displayed(tab/group)=Description (OPS OSM Protection Switch/OPS OSM Specifics)

evaluationTimer Protection switch evaluation timer.

type=long
minimum=0
maximum=65535
units=ms
Displayed(tab/group)=Evaluation Timer (OPS OSM Protection Switch/OPS OSM Specifics)

externalCommand Protection switch external command status.

type=string
access=read-only
Displayed(tab/group)=External Command (OPS OSM Protection Switch/OPS OSM Specifics)

holdOffTimer Protection switch hold-off timer.

type=long
default=1
minimum=1
maximum=65535
units=ms
Displayed(tab/group)=Hold Off Timer (OPS OSM Protection Switch/OPS OSM Specifics)

maxSwitchCount Maximum number of switch counts.

type=long
minimum=0
maximum=65535
Displayed(tab/group)=Max Switch Count (OPS OSM Protection Switch/OPS OSM Specifics)

osmDsvactualSelectorPosition "The actual position of the PMU-D BAND selector."

type=vwm.OpsOsmDsvSelectorPosition
access=read-only
Displayed(tab/group)=Actual Selector Position (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvapsActive "Indicates whether automatic protection switching is active for this OSM-DSV."

type=generic.TruthValue
access=read-only
Displayed(tab/group)=Aps Active (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvconfigSelectorPosition "The actual position of the PMU-D BAND selector."

type=vwm.OpsOsmDsvSelectorPosition
Displayed(tab/group)=Configured Selector Position (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsveVoaSigIn "Actual attenuation value of the eVOA in the SIG IN port."

type=float
access=read-only
Displayed(tab/group)=E Voa Sig In (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsveVoaSigInAOut "Attenuation value of the eVOA in the SIG IN port in case the TX selector points to the A OUT port."

type=float
minimum=0
maximum=15
units=dB
Displayed(tab/group)=E Voa Sig In A Out (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsveVoaSigInBOut "Attenuation value of the eVOA in the SIG IN port in case the TX selector points to the B OUT port."

type=float
minimum=0
maximum=15
units=dB
Displayed(tab/group)=E Voa Sig In B Out (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsveVoaSigOut "Actual attenuation value of the eVOA in the SIG OUT port."

type=float
access=read-only
Displayed(tab/group)=E Voa Sig Out (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsveVoaSigOutAIn "Attenuation value of the eVOA in the SIG OUT port in case the RX selector points to the A IN port."

type=float
minimum=0
maximum=15
units=dB
Displayed(tab/group)=E Voa Sig Out A In (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsveVoaSigOutBIn "Attenuation value of the eVOA in the SIG OUT port in case the RX selector points to the B IN port."

type=float
minimum=0
maximum=15
units=dB
Displayed(tab/group)=E Voa Sig Out B In (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvoprA "Optical Power Received (OPR) defect status of port A."

type=generic.TruthValue
access=read-only
Displayed(tab/group)=OPR A (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvoprB "Optical Power Received (OPR) defect status of port B."

type=generic.TruthValue
access=read-only
Displayed(tab/group)=OPR B (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvoprSIG "Optical Power Received (OPR) defect status of port SIG."

type=generic.TruthValue
access=read-only
Displayed(tab/group)=OPR SIG (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvopsOsmDsvAvailabilityStatus Indicates the availability of the following read-only data of the current row : - tnVwmMsOpsOsmDsvRxPowerA - tnVwmMsOpsOsmDsvRxPowerB - tnVwmMsOpsOsmDsvRxPowerSIG - tnVwmMsOpsOsmDsvTxPowerSIG - tnVwmMsOpsOsmDsvEVoaSigIn - tnVwmMsOpsOsmDsvEVoaSigOut

type=vwm.VwmMsInventoryStatus
access=read-only
Displayed(tab/group)=Availability Status (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvrxPowerA "Power of input signal of port A."

type=float
access=read-only
Displayed(tab/group)=Rx Power A (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvrxPowerB "Power of input signal of port B."

type=float
access=read-only
Displayed(tab/group)=Rx Power B (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvrxPowerSIG "Power of input signal of port SIG."

type=float
access=read-only
Displayed(tab/group)=Rx Power SIG (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvthresholdA Power threshold for the input signal of port A.

type=float
default=-27.0
minimum=-30
maximum=35
units=dBm
Displayed(tab/group)=Threshold A (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvthresholdB Power threshold for the input signal of port B.

type=float
default=-27.0
minimum=-30
maximum=35
units=dBm
Displayed(tab/group)=Threshold B (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvthresholdHysteresis Power Hysteresis for input signals.

type=float
default=1.0
minimum=1
maximum=3
units=dB
Displayed(tab/group)=Threshold Hysteresis (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvthresholdSigIn Power threshold for the input signal of port SIG.

type=float
default=-27.0
minimum=-30
maximum=35
units=dBm
Displayed(tab/group)=Threshold Sig In (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvthresholdSigOut Power threshold for the output signal of port SIG.

type=float
default=-27.0
minimum=-30
maximum=35
units=dBm
Displayed(tab/group)=Threshold Sig Out (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

osmDsvtxPowerSIG "Power of output signal of port SIG."

type=float
access=read-only
Displayed(tab/group)=Tx Power SIG (OPS OSM Protection Switch/OPS OSM-DSV Specifics)

powerA Power of input signal of port A.

type=float
access=read-only
units=dBm
Displayed(tab/group)=Receive Power A (OPS OSM Protection Switch/OPS OSM Specifics)

powerB Power of input signal of port B.

type=float
access=read-only
units=dBm
Displayed(tab/group)=Receive Power B (OPS OSM Protection Switch/OPS OSM Specifics)

powerSIG Power of input signal of port SIG.

type=float
access=read-only
units=dBm
Displayed(tab/group)=Receive Power SIG (OPS OSM Protection Switch/OPS OSM Specifics)

resetSwitchCount Reset Switch Count

type=generic.TruthValue
Displayed(tab/group)=Reset Switch Count (OPS OSM Protection Switch/OPS OSM Specifics)

rxPos RX selector position.

type=string
access=read-only
Displayed(tab/group)=RX selector position (OPS OSM Protection Switch/OPS OSM Specifics)

shelfId shelf identifier

type=int
default=1
minimum=1
maximum=2047

slotId slot identifier

type=int
default=1
minimum=1
maximum=255

state Protection switch status.

type=string
access=read-only
Displayed(tab/group)=Switch Status (OPS OSM Protection Switch/OPS OSM Specifics)

switchCommand User configurable protection switch command.

type=vwm.OpsOsmSwitchCommand
Displayed(tab/group)=Switch Command (OPS OSM Protection Switch/OPS OSM Specifics)

switchCount Actual number of switch counts.

type=long
access=read-only
minimum=0
maximum=4294967295
Displayed(tab/group)=Switch Count (OPS OSM Protection Switch/OPS OSM Specifics)

switchCountResetTimer Protection switch count reset timer.

type=long
minimum=0
maximum=4294967295
units=ms
Displayed(tab/group)=Switch Count Reset Timer (OPS OSM Protection Switch/OPS OSM Specifics)

thresholdA Power threshold for the input signal of port A.

type=float
minimum=-30
maximum=35
units=dBm
Displayed(tab/group)=Threshold A (OPS OSM Protection Switch/OPS OSM Specifics)

thresholdB Power threshold for the input signal of port B.

type=float
minimum=-30
maximum=35
units=dBm
Displayed(tab/group)=Threshold B (OPS OSM Protection Switch/OPS OSM Specifics)

thresholdHysteresis Power Hysteresis for input signals.

type=float
default=1.0
minimum=1
maximum=3
units=dB
Displayed(tab/group)=Threshold Hysteresis (OPS OSM Protection Switch/OPS OSM Specifics)

thresholdSIG Power threshold for the input signal of port SIG.

type=float
minimum=-30
maximum=35
units=dBm
Displayed(tab/group)=Threshold SIG (OPS OSM Protection Switch/OPS OSM Specifics)

txPos TX selector position.

type=string
access=read-only
Displayed(tab/group)=TX selector position (OPS OSM Protection Switch/OPS OSM Specifics)

  
Properties inherited from ManagedObject
actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed
 
Supported Network Elements
1830 VWM OSU Supported from 8.3.0
Product Specifics
1830 VWM OSU 8.3
1830 VWM OSU 8.4
1830 VWM OSU 8.5
1830 VWM OSU 9.0