| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| albCtsInControlLead |
type=tdmequipment.ControlLeadType default=high Displayed(tab/group)= • tdmequipment.SerialChannel ALB / CTS Input (Channel/Control Leads) |
| albCtsMonControlLead |
type=tdmequipment.SBitSigType default=off Displayed(tab/group)= • tdmequipment.SerialChannel ALB / CTS Monitor (Channel/Control Leads) |
| channelType |
type=tdmequipment.SerialType access=read-only default=rs232 Displayed(tab/group)= • tdmequipment.SerialChannel Channel Type (Channel) |
| characterLength |
type=int default=8 minimum=6 maximum=8 Displayed(tab/group)= • tdmequipment.SerialChannel Character Length (Channel/Asynchronous) |
| clockSource |
type=tdmequipment.SerialClockSourceType default=slave Displayed(tab/group)= • tdmequipment.SerialChannel Clock Source (Channel) |
| controlLeadsSignal |
type=string access=read-only maximum=23 Displayed(tab/group)= • tdmequipment.SerialChannel Control Leads Signal (Channel/Control Leads) |
| controlLeadsState |
type=string access=read-only maximum=23 Displayed(tab/group)= • tdmequipment.SerialChannel Control Leads State (Channel/Control Leads) |
| ctsAlbOutControlLead |
type=tdmequipment.ControlLeadType default=high Displayed(tab/group)= • tdmequipment.SerialChannel CTS / ALB Output (Channel/Control Leads) |
| dataPosition |
type=tdmequipment.DataPositionType default=f0b5 Displayed(tab/group)= • tdmequipment.SerialChannel HCM Data Position (Channel) |
| dcdRtsIOutControlLead |
type=tdmequipment.ControlLeadType default=high Displayed(tab/group)= • tdmequipment.SerialChannel DCD / RTS / I / C Output (Channel/Control Leads) |
| dsrDtrOutControlLead |
type=tdmequipment.ControlLeadType default=high Displayed(tab/group)= • tdmequipment.SerialChannel DSR / DTR Output (Channel/Control Leads) |
| dtrDsrInControlLead |
type=tdmequipment.ControlLeadType default=high Displayed(tab/group)= • tdmequipment.SerialChannel DTR / DSR Input (Channel/Control Leads) |
| dtrDsrmMonControlLead |
type=tdmequipment.SBitSigType default=off Displayed(tab/group)= • tdmequipment.SerialChannel DTR / DSR Monitor (Channel/Control Leads) |
| duplex |
type=tdmequipment.DuplexType default=fullDuplex Displayed(tab/group)= • tdmequipment.SerialChannel Duplex (Channel) |
| gender |
type=tdmequipment.SerialGenderType default=dce Displayed(tab/group)= • tdmequipment.SerialChannel Gender (Channel) |
| holdDownTime |
Specifies the time used for the hold-timer for associated Continuity Check (CC) Session
down event dampening.
type=int default=0 minimum=0 maximum=100 units=miliseconds Displayed(tab/group)= • tdmequipment.SerialChannel Hold Time Down (Channel/Hold Time) |
| holdUpTime |
The value of holdUpTime is used to configure the hold-timer for link up event dampening.
type=int default=0 minimum=0 maximum=100 units=miliseconds Displayed(tab/group)= • tdmequipment.SerialChannel Hold Time Up (Channel/Hold Time) |
| invertClock |
Specifies whether to invert the clock edge that the interface samples for received data (if local gender is DCE) or transmitted data (if local gender is DTE).
Inverting the clock may correct issues such as those related to phase shift.
For example, data changes state near the interface's sampling clock edge. Contributors to phase shift variance include, but are not limited to:cable length and interface rate.
type=boolean default=false Displayed(tab/group)= • tdmequipment.SerialChannel Invert Clock (Channel) |
| loopback |
type=tdmequipment.SerialLoopbackType default=none Displayed(tab/group)= • tdmequipment.SerialChannel Loopback (Channel) |
| monClockDev |
To enable/disbale debounce clock deviation.
type=boolean default=false Displayed(tab/group)= • tdmequipment.SerialChannel Enable Clock Deviation Monitoring (Channel/Clock Deviation Monitoring) |
| monClockDevClr |
Specifies the amount of time to debounce no clock deviation before de-asserting the port fault condition, 'monClockDeviation'.
No clock deviation is detected when the external clock does not exceed a +/- 5% deviation from the internal interface rate clock.
type=int default=0 minimum=0 maximum=100 units=seconds Displayed(tab/group)= • tdmequipment.SerialChannel Clear (Channel/Clock Deviation Monitoring) |
| monClockDevRaise |
Specifies the amount of time to debounce clock deviation before asserting the port fault condition, 'monClockDeviation'.
Clock deviation is detected when the external clock exceeds a +/- 5% deviation from the internal interface rate clock.
type=int default=0 minimum=0 maximum=100 units=seconds Displayed(tab/group)= • tdmequipment.SerialChannel Raise (Channel/Clock Deviation Monitoring) |
| monDataInact |
Enable/Disable debounce data inactivity.
type=boolean default=false Displayed(tab/group)= • tdmequipment.SerialChannel Enable Data Inactivity Monitoring (Channel/Data Inactivity Monitoring) |
| monDataInactClr |
Specifies the amount of time to debounce data activity before de-asserting the port fault condition, 'monDataInactivity'.
type=int default=0 minimum=0 maximum=100 units=seconds Displayed(tab/group)= • tdmequipment.SerialChannel Clear (Channel/Data Inactivity Monitoring) |
| monDataInactRaise |
Specifies the amount of time to debounce data inactivity before asserting the port fault condition, 'monDataInactivity'.
type=int default=0 minimum=0 maximum=100 units=seconds Displayed(tab/group)= • tdmequipment.SerialChannel Raise (Channel/Data Inactivity Monitoring) |
| multidrop |
type=tdmequipment.MultidropType default=disabled Displayed(tab/group)= • tdmequipment.SerialChannel Multidrop Data Bridge (Channel) |
| parity |
type=tdmequipment.ParityType default=none Displayed(tab/group)= • tdmequipment.SerialChannel Parity (Channel/Asynchronous) |
| rdlRiInControlLead |
type=tdmequipment.ControlLeadType default=high Displayed(tab/group)= • tdmequipment.SerialChannel RDL / RI Input (Channel/Control Leads) |
| rdlRiMonControlLead |
type=tdmequipment.SBitSigType default=off Displayed(tab/group)= • tdmequipment.SerialChannel RDL / RI Monitor (Channel/Control Leads) |
| reportAlarmBits |
type=tdmequipment.SerialChannelReportAlarmBitmask default=96 Displayed(tab/group)= • tdmequipment.SerialChannel Report Alarms (Channel/Monitoring) |
| reportAlarmStatus |
type=tdmequipment.SerialChannelReportAlarmBitmask access=read-only default=0 Displayed(tab/group)= • tdmequipment.SerialChannel Outstanding Alarms (Channel/Monitoring) |
| riRdlOutControlLead |
type=tdmequipment.ControlLeadType default=high Displayed(tab/group)= • tdmequipment.SerialChannel RI / RDL Output (Channel/Control Leads) |
| rtsDcdCInControlLead |
type=tdmequipment.ControlLeadType default=high Displayed(tab/group)= • tdmequipment.SerialChannel RTS / DCD / C / I Input (Channel/Control Leads) |
| rtsDcdCMonControlLead |
type=tdmequipment.SBitSigType default=off Displayed(tab/group)= • tdmequipment.SerialChannel RTS / DCD / C / I Monitor (Channel/Control Leads) |
| sBitSig |
type=tdmequipment.SBitSigType default=on Displayed(tab/group)= • tdmequipment.SerialChannel S-Bit Signalling (Channel) |
| serialMode |
type=tdmequipment.SerialModeType default=synchronous Displayed(tab/group)= • tdmequipment.SerialChannel Device Mode (Channel) |
| speed |
type=tdmequipment.SpeedType default=speed9600 Displayed(tab/group)= • tdmequipment.SerialChannel Speed (Channel) |
| stopBits |
type=int default=1 minimum=1 maximum=2 Displayed(tab/group)= • tdmequipment.SerialChannel Stop Bits (Channel/Asynchronous) |
| Properties inherited from equipment.ChannelSpecifics |
|---|
| channelRelativeName, physicalPortSnmpId |
| Properties inherited from equipment.PortSpecifics |
|---|
| cardSubType, isPortChannelALeaf, mprFraming, mprLineLength, portClass, portId, snmpPortId, specificCardType, upProtocols |
| Properties inherited from equipment.EquipmentSpecifics |
|---|
| displayedName, lockOlcState, olcState, shelfId, siteId, siteName |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |
| Supported Network Elements | |
|---|---|
| 7705 SAR | |
| 7705 SAR H | |
| Product Specifics | |
| 7705 SAR H (all versions) | |
| 7705 SAR H 20.0 | |
| 7705 SAR H 21.0 | |
| 7705 SAR H 22.0 | |
| 7705 SAR H 23.0 | |
| 7705 SAR H 24.0 | |
| 7705 SAR H 25.0 | |
| 7705 SAR H 9.0 | |
| 7705 SAR 20.0 | |
| 7705 SAR 21.0 | |
| 7705 SAR 22.0 | |
| 7705 SAR 23.0 | |
| 7705 SAR 24.0 | |
| 7705 SAR 25.0 | |