tdmequipment
SerialChannelSpecifics



public class SerialChannelSpecifics

Properties
albCtsInControlLead

type=tdmequipment.ControlLeadType
default=high
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  ALB / CTS Input (Channel/Control Leads)

albCtsMonControlLead

type=tdmequipment.SBitSigType
default=off
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  ALB / CTS Monitor (Channel/Control Leads)

channelType

type=tdmequipment.SerialType
access=read-only
default=rs232
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Channel Type (Channel)

characterLength

type=int
default=8
minimum=6
maximum=8
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Character Length (Channel/Asynchronous)

clockSource

type=tdmequipment.SerialClockSourceType
default=slave
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Clock Source (Channel)

controlLeadsSignal

type=string
access=read-only
maximum=23
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Control Leads Signal (Channel/Control Leads)

controlLeadsState

type=string
access=read-only
maximum=23
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Control Leads State (Channel/Control Leads)

ctsAlbOutControlLead

type=tdmequipment.ControlLeadType
default=high
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  CTS / ALB Output (Channel/Control Leads)

dataPosition

type=tdmequipment.DataPositionType
default=f0b5
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  HCM Data Position (Channel)

dcdRtsIOutControlLead

type=tdmequipment.ControlLeadType
default=high
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  DCD / RTS / I / C Output (Channel/Control Leads)

dsrDtrOutControlLead

type=tdmequipment.ControlLeadType
default=high
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  DSR / DTR Output (Channel/Control Leads)

dtrDsrInControlLead

type=tdmequipment.ControlLeadType
default=high
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  DTR / DSR Input (Channel/Control Leads)

dtrDsrmMonControlLead

type=tdmequipment.SBitSigType
default=off
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  DTR / DSR Monitor (Channel/Control Leads)

duplex

type=tdmequipment.DuplexType
default=fullDuplex
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Duplex (Channel)

gender

type=tdmequipment.SerialGenderType
default=dce
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Gender (Channel)

holdDownTime Specifies the time used for the hold-timer for associated Continuity Check (CC) Session down event dampening.

type=int
default=0
minimum=0
maximum=100
units=miliseconds
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Hold Time Down (Channel/Hold Time)

holdUpTime The value of holdUpTime is used to configure the hold-timer for link up event dampening.

type=int
default=0
minimum=0
maximum=100
units=miliseconds
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Hold Time Up (Channel/Hold Time)

invertClock Specifies whether to invert the clock edge that the interface samples for received data (if local gender is DCE) or transmitted data (if local gender is DTE). Inverting the clock may correct issues such as those related to phase shift. For example, data changes state near the interface's sampling clock edge. Contributors to phase shift variance include, but are not limited to:cable length and interface rate.

type=boolean
default=false
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Invert Clock (Channel)

loopback

type=tdmequipment.SerialLoopbackType
default=none
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Loopback (Channel)

monClockDev To enable/disbale debounce clock deviation.

type=boolean
default=false
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Enable Clock Deviation Monitoring (Channel/Clock Deviation Monitoring)

monClockDevClr Specifies the amount of time to debounce no clock deviation before de-asserting the port fault condition, 'monClockDeviation'. No clock deviation is detected when the external clock does not exceed a +/- 5% deviation from the internal interface rate clock.

type=int
default=0
minimum=0
maximum=100
units=seconds
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Clear (Channel/Clock Deviation Monitoring)

monClockDevRaise Specifies the amount of time to debounce clock deviation before asserting the port fault condition, 'monClockDeviation'. Clock deviation is detected when the external clock exceeds a +/- 5% deviation from the internal interface rate clock.

type=int
default=0
minimum=0
maximum=100
units=seconds
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Raise (Channel/Clock Deviation Monitoring)

monDataInact Enable/Disable debounce data inactivity.

type=boolean
default=false
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Enable Data Inactivity Monitoring (Channel/Data Inactivity Monitoring)

monDataInactClr Specifies the amount of time to debounce data activity before de-asserting the port fault condition, 'monDataInactivity'.

type=int
default=0
minimum=0
maximum=100
units=seconds
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Clear (Channel/Data Inactivity Monitoring)

monDataInactRaise Specifies the amount of time to debounce data inactivity before asserting the port fault condition, 'monDataInactivity'.

type=int
default=0
minimum=0
maximum=100
units=seconds
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Raise (Channel/Data Inactivity Monitoring)

multidrop

type=tdmequipment.MultidropType
default=disabled
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Multidrop Data Bridge (Channel)

parity

type=tdmequipment.ParityType
default=none
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Parity (Channel/Asynchronous)

rdlRiInControlLead

type=tdmequipment.ControlLeadType
default=high
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  RDL / RI Input (Channel/Control Leads)

rdlRiMonControlLead

type=tdmequipment.SBitSigType
default=off
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  RDL / RI Monitor (Channel/Control Leads)

reportAlarmBits

type=tdmequipment.SerialChannelReportAlarmBitmask
default=96
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Report Alarms (Channel/Monitoring)

reportAlarmStatus

type=tdmequipment.SerialChannelReportAlarmBitmask
access=read-only
default=0
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Outstanding Alarms (Channel/Monitoring)

riRdlOutControlLead

type=tdmequipment.ControlLeadType
default=high
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  RI / RDL Output (Channel/Control Leads)

rtsDcdCInControlLead

type=tdmequipment.ControlLeadType
default=high
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  RTS / DCD / C / I Input (Channel/Control Leads)

rtsDcdCMonControlLead

type=tdmequipment.SBitSigType
default=off
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  RTS / DCD / C / I Monitor (Channel/Control Leads)

sBitSig

type=tdmequipment.SBitSigType
default=on
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  S-Bit Signalling (Channel)

serialMode

type=tdmequipment.SerialModeType
default=synchronous
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Device Mode (Channel)

speed

type=tdmequipment.SpeedType
default=speed9600
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Speed (Channel)

stopBits

type=int
default=1
minimum=1
maximum=2
Displayed(tab/group)=
    •  tdmequipment.SerialChannel  Stop Bits (Channel/Asynchronous)

  
Properties inherited from equipment.ChannelSpecifics
channelRelativeName, physicalPortSnmpId
 
Properties inherited from equipment.PortSpecifics
cardSubType, isPortChannelALeaf, mprFraming, mprLineLength, portClass, portId, snmpPortId, specificCardType, upProtocols
 
Properties inherited from equipment.EquipmentSpecifics
displayedName, lockOlcState, olcState, shelfId, siteId, siteName
 
Properties inherited from ManagedObject
actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed
 
Supported Network Elements
7705 SAR
7705 SAR H
Product Specifics
7705 SAR H (all versions)
7705 SAR H 20.0
7705 SAR H 21.0
7705 SAR H 22.0
7705 SAR H 23.0
7705 SAR H 24.0
7705 SAR H 25.0
7705 SAR H 9.0
7705 SAR 20.0
7705 SAR 21.0
7705 SAR 22.0
7705 SAR 23.0
7705 SAR 24.0
7705 SAR 25.0