| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| bits2AdministrativeState |
type=sonet.AdministrativeState access=read-only default=down Displayed(tab/group)=Administrative State (/BITS2) |
| bits2Alarms |
type=sonet.ProblemCode access=read-only default=0 Displayed(tab/group)=Not Qualified Due To (/BITS2) |
| bits2InUse |
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Selected For Use (/BITS2) |
| bits2InputState |
type=sonet.AdministrativeState default=down Displayed(tab/group)=Input Administrative State (/BITS2) |
| bits2OutputState |
type=sonet.AdministrativeState default=down Displayed(tab/group)=Output Administrative State (/BITS2) |
| bits2Qualified |
type=sonet.TimingReferenceQualified access=read-only default=0 Displayed(tab/group)=Qualified For Use (/BITS2) |
| bits2State |
type=sonet.RefInState access=read-only Displayed(tab/group)=Not Selected Due To (/BITS2) |
| bits2TimingReferenceRxQltyLevel |
type=sonet.SystemQualityLevelType access=read-only Displayed(tab/group)=Received Quality Level (/BITS2) |
| bits2TimingReferenceTxQltyLevel |
type=sonet.SystemQualityLevelType access=read-only Displayed(tab/group)=Transmitted Quality Level (/BITS2) |
| bitsAdministrativeState |
type=sonet.AdministrativeState default=down Displayed(tab/group)=Input Administrative State (/BITS/BITS1) |
| bitsAlarms |
type=sonet.ProblemCode access=read-only default=0 Displayed(tab/group)=Not Qualified Due To (/BITS/BITS1) |
| bitsInUse |
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Selected For Use (/BITS/BITS1) |
| bitsInterfaceType |
type=sonet.BitsIfType default=t1_esf Displayed(tab/group)=Interface Type (/BITS/BITS1) |
| bitsOutQlMinimum |
type=sonet.QlMinimum default=unknown Displayed(tab/group)=Output Ql Minimum (/BITS/BITS1) |
| bitsOutSquelch |
The value specifies whether or not to squelch the output signal.
type=generic.TruthValue default=false Displayed(tab/group)=Output Squelch (/BITS/BITS1) |
| bitsOutputRefSel |
type=sonet.BitsTimingSourcePreference access=read-only Displayed(tab/group)=Output Reference Selected (/BITS/BITS1) |
| bitsOutputState |
type=sonet.AdministrativeState default=down Displayed(tab/group)=Output Administrative State (/BITS/BITS1) |
| bitsQualified |
type=sonet.TimingReferenceQualified access=read-only default=0 Displayed(tab/group)=Qualified For Use (/BITS/BITS1) |
| bitsQualityLevel |
type=sonet.BitsReferenceQualityLevelType default=unknown Displayed(tab/group)=Quality Level Override (/BITS/BITS1) |
| bitsSource |
type=sonet.SourceType default=lineRef Displayed(tab/group)=Output Source (/BITS/BITS1) |
| bitsState |
type=sonet.RefInState access=read-only Displayed(tab/group)=Not Selected Due To (/BITS/BITS1) |
| bitsTimingReferenceRxQltyLevel |
type=sonet.SystemQualityLevelType access=read-only Displayed(tab/group)=Received Quality Level (/BITS/BITS1) |
| bitsTimingReferenceTxQltyLevel |
type=sonet.SystemQualityLevelType access=read-only Displayed(tab/group)=Transmitted Quality Level (/BITS/BITS1) |
| bitslineLength |
type=sonet.LineLengthType default=length0To110 Displayed(tab/group)=Output Line Length (/BITS/BITS1) |
| equipmentClock |
This object is used to enable/disable the whole EEC function.
type=generic.TruthValue default=false Displayed(tab/group)=Network Equipment Clock |
| externalInIfAdminStatus |
The desired administrative status of the external input timing reference. For 7705 only
type=sonet.AdministrativeState default=down Displayed(tab/group)=Administrative State (/External Timing Reference) |
| externalInIfType |
The interface type of the external input timing reference. For 7705 only
type=sonet.ExternalIfType default=two_mhz_square Displayed(tab/group)=Input Type (/External Timing Reference) |
| externalInTimingReferenceAlarms |
type=sonet.ProblemCode access=read-only default=0 Displayed(tab/group)=Not Qualified Due To (/External Timing Reference) |
| externalInTimingReferenceInUse |
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Selected For Use (/External Timing Reference) |
| externalInTimingReferenceQualified |
type=sonet.TimingReferenceQualified access=read-only default=0 Displayed(tab/group)=Qualified For Use (/External Timing Reference) |
| externalInTimingReferenceQualityLevel |
type=sonet.ExternalReferenceQualityLevelType default=unknown Displayed(tab/group)=Quality Level (/External Timing Reference) |
| externalInTimingReferenceState |
type=sonet.RefInState access=read-only Displayed(tab/group)=Not Selected Due To (/External Timing Reference) |
| externalInputImpedanceType |
The input impedance value of the external input timing interface. For 7705 only
type=sonet.ExternalInputImpedanceType default=high_impedance Displayed(tab/group)=Impedance Type (/External Timing Reference) |
| externalOutIfType |
The interface type of the external output timing reference, for 7705 only
type=sonet.ExternalIfType default=two_mhz_square Displayed(tab/group)=Output Type (/External Timing Reference) |
| fifthTimingReferenceInput |
type=sonet.TimingSourcePreference default=bits2 Displayed(tab/group)=Fifth Timing Reference Input (/Reference Order) |
| firstTimingRefBitsInterfaceType |
type=sonet.BitsIfType default=t1_esf Displayed(tab/group)=BITS Interface Type (/Timing Reference One) |
| firstTimingReferenceAdministrativeState |
type=sonet.AdministrativeState default=down Displayed(tab/group)=Administrative State (/Timing Reference One) |
| firstTimingReferenceAlarms |
type=sonet.ProblemCode access=read-only default=0 Displayed(tab/group)=Not Qualified Due To (/Timing Reference One) |
| firstTimingReferenceInUse |
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Selected For Use (/Timing Reference One) |
| firstTimingReferenceInput |
type=sonet.TimingSourcePreference default=bits Displayed(tab/group)=First Timing Reference Input (/Reference Order) |
| firstTimingReferenceInterfaceName |
type=string access=read-only default= maximum=252 |
| firstTimingReferenceInterfacePointer |
type=Pointer default= Displayed(tab/group)=Timing Reference Interface (/Timing Reference One) |
| firstTimingReferencePortName |
type=string default= maximum=252 |
| firstTimingReferencePortPointer |
type=Pointer default= Displayed(tab/group)=Timing Reference (/Timing Reference One) |
| firstTimingReferencePortSnmpId |
type=long access=read-only default=0 |
| firstTimingReferenceQualified |
type=sonet.TimingReferenceQualified access=read-only default=0 Displayed(tab/group)=Qualified For Use (/Timing Reference One) |
| firstTimingReferenceQualityLevel |
type=sonet.ReferenceQualityLevelType default=unknown Displayed(tab/group)=Quality Level Override (/Timing Reference One) |
| firstTimingReferenceRxQltyLevel |
type=sonet.SystemQualityLevelType access=read-only Displayed(tab/group)=Received Quality Level (/Timing Reference One) |
| firstTimingReferenceSaBit |
type=long default=8 minimum=4 maximum=8 Displayed(tab/group)=SSM (/Timing Reference One) |
| firstTimingReferenceSourceBit |
type=long access=read-only default=0 |
| firstTimingReferenceSourceBitPointer |
type=Pointer default= Displayed(tab/group)=Timing Reference Source Bit (/Timing Reference One) |
| firstTimingReferenceSrcPtpClock |
type=int default=0 minimum=0 maximum=2 Displayed(tab/group)=First Timing Reference Ptp Clock (/Timing Reference One) |
| firstTimingReferenceState |
type=sonet.RefInState access=read-only Displayed(tab/group)=Not Selected Due To (/Timing Reference One) |
| firstTimingReferenceType |
type=sonet.ReferenceType default=port Displayed(tab/group)=Type (/Timing Reference One) |
| fourthTimingReferenceInput |
type=sonet.TimingSourcePreference default=ptp Displayed(tab/group)=Fourth Timing Reference Input (/Reference Order) |
| freqOffset |
type=long access=read-only units=ppm Displayed(tab/group)=Frequency Offset |
| gnssAdminStatus |
The value of gnssAdminStatus indicates the administrative status of the Global Navigation Satellite System (GNSS)
timing reference
type=sonet.AdministrativeState default=down Displayed(tab/group)=Administrative State (/GNSS) |
| gnssAlarms |
The value of gnssAlarms indicates the alarms on the GNSS timing reference. If any of the bits is set to '1', then the GNSS reference is
disqualified by the timing subsystem and the value of qualified is set to 'not-qualified'.
type=sonet.ProblemCode access=read-only default=0 Displayed(tab/group)=Not Qualified Due To (/GNSS) |
| gnssInUse |
The value of inUse indicates whether the GNSS timing reference is presently being used by the synchronous timing
subsystem. If it is in use, tmnxSyncIfTimingFreqOffset indicates the frequency offset for this reference.
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Selected For Use (/GNSS) |
| gnssQltyLevel |
The value of gnssQltyLevel indicates the configured Quality Level of the GNSS timing reference. A value of 'unknown (0)'
indicates GNSS is not forced to a specific quality level.
type=sonet.SystemQualityLevelType default=unknown Displayed(tab/group)=Quality Level Override (/GNSS) |
| gnssQualified |
The value of gnssQualified indicates whether the GNSS timing reference is qualified for use by the synchronous timing
subsystem. If qualified is set to 'not-qualified',then the object timingAlarm gives the reason for
disqualification.
type=sonet.TimingReferenceQualified access=read-only default=0 Displayed(tab/group)=Qualified For Use (/GNSS) |
| gnssState |
The value of gnssState indicates the operational state of the GNSS timing reference.
type=sonet.PtpInState access=read-only Displayed(tab/group)=Not Selected Due To (/GNSS) |
| gnssTimingRefRxQltyLevel |
The value of gnssTimingRefRxQltyLevel indicates the received SSM Quality Level of the GNSS timing reference.
type=sonet.SystemQualityLevelType access=read-only Displayed(tab/group)=Received Quality Level (/GNSS) |
| isPtpClockModeEnabled |
type=boolean default=false Displayed(tab/group)=TC Enabled (/1588) |
| mateCPMReferenceAlarms |
type=sonet.ProblemCode access=read-only default=0 Displayed(tab/group)=Not Qualified Due To (/Reference Mate CPM) |
| mateCPMReferenceInUse |
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Selected For Use (/Reference Mate CPM) |
| mateCPMReferenceQualified |
type=sonet.TimingReferenceQualified access=read-only default=0 Displayed(tab/group)=Qualified For Use (/Reference Mate CPM) |
| mateCPMReferenceState |
type=sonet.RefInState access=read-only default=0 Displayed(tab/group)=Not Selected Due To (/Reference Mate CPM) |
| minQualityLevel |
The value specifies the minimum acceptable quality level that a signal must have for it to be considered for
selection by the system timing module.
type=sonet.MinimumQualityLevelType default=unknown Displayed(tab/group)=Minimum Quality Level |
| oesShelfId |
type=int default=0 |
| phyShelfClass |
type=equipment.PhysicalShelfClass default=unknown |
| primaryCpmCardNumber |
type=int access=read-only default=1 |
| primaryCpmSlotId |
type=int access=read-only default=1 |
| primarySyncProtectionUnitCriteria |
type=sonet.SyncProtectionUnitCriteria Displayed(tab/group)=Primary Criteria (/Synchronization Protection) |
| primarySyncProtectionUnitStatus |
type=mpr.SwitchStatus Displayed(tab/group)=Primary Status (/Synchronization Protection) |
| primaryTimingReferenceType |
type=sonet.MprSyncReferenceType default=freeRunLocalOscillator Displayed(tab/group)=Primary Reference Type (/Reference Type) |
| ptpAdministrativeState |
type=sonet.AdministrativeState default=down Displayed(tab/group)=Administrative State (/PTP) |
| ptpAlarms |
type=sonet.ProblemCode access=read-only default=0 Displayed(tab/group)=Not Qualified Due To (/PTP) |
| ptpInUse |
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Selected For Use (/PTP) |
| ptpQualified |
type=sonet.TimingReferenceQualified access=read-only default=0 Displayed(tab/group)=Qualified For Use (/PTP) |
| ptpQualityLevel |
type=sonet.SystemQualityLevelType default=unknown Displayed(tab/group)=Quality Level Override (/PTP) |
| ptpState |
type=sonet.PtpInState access=read-only Displayed(tab/group)=Not Selected Due To (/PTP) |
| ptpTimingReferenceRxQltyLevel |
type=sonet.SystemQualityLevelType access=read-only Displayed(tab/group)=Received Quality Level (/PTP) |
| qualityLevel |
type=sonet.ReferenceQualityLevel default=enabled Displayed(tab/group)=Quality Level Reference |
| revertive |
type=generic.TruthValue default=false Displayed(tab/group)=Reference Input Mode (revertive) |
| role |
type=sonet.RoleStatus default=master Displayed(tab/group)=Role |
| saBit |
type=long default=8 minimum=4 maximum=8 Displayed(tab/group)=SSM (/BITS/BITS1) |
| secondTimingRefBitsInterfaceType |
type=sonet.BitsIfType default=t1_esf Displayed(tab/group)=BITS Interface Type (/Timing Reference Two) |
| secondTimingReferenceAdministrativeState |
type=sonet.AdministrativeState default=down Displayed(tab/group)=Administrative State (/Timing Reference Two) |
| secondTimingReferenceAlarms |
type=sonet.ProblemCode access=read-only default=0 Displayed(tab/group)=Not Qualified Due To (/Timing Reference Two) |
| secondTimingReferenceInUse |
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Selected For Use (/Timing Reference Two) |
| secondTimingReferenceInput |
type=sonet.TimingSourcePreference default=referenceOne Displayed(tab/group)=Second Timing Reference Input (/Reference Order) |
| secondTimingReferenceInterfaceName |
type=string access=read-only default= maximum=252 |
| secondTimingReferenceInterfacePointer |
type=Pointer default= Displayed(tab/group)=Timing Reference Interface (/Timing Reference Two) |
| secondTimingReferencePortName |
type=string default= maximum=252 |
| secondTimingReferencePortPointer |
type=Pointer default= Displayed(tab/group)=Timing Reference (/Timing Reference Two) |
| secondTimingReferencePortSnmpId |
type=long access=read-only default=0 |
| secondTimingReferenceQualified |
type=sonet.TimingReferenceQualified access=read-only default=0 Displayed(tab/group)=Qualified For Use (/Timing Reference Two) |
| secondTimingReferenceQualityLevel |
type=sonet.ReferenceQualityLevelType default=unknown Displayed(tab/group)=Quality Level Override (/Timing Reference Two) |
| secondTimingReferenceRxQltyLevel |
type=sonet.SystemQualityLevelType access=read-only Displayed(tab/group)=Received Quality Level (/Timing Reference Two) |
| secondTimingReferenceSaBit |
type=long default=8 minimum=4 maximum=8 Displayed(tab/group)=SSM (/Timing Reference Two) |
| secondTimingReferenceSourceBit |
type=long access=read-only default=0 |
| secondTimingReferenceSourceBitPointer |
type=Pointer default= Displayed(tab/group)=Timing Reference Source Bit (/Timing Reference Two) |
| secondTimingReferenceSrcPtpClock |
type=int default=0 minimum=0 maximum=2 Displayed(tab/group)=Second Timing Reference Ptp Clock (/Timing Reference Two) |
| secondTimingReferenceState |
type=sonet.RefInState access=read-only Displayed(tab/group)=Not Selected Due To (/Timing Reference Two) |
| secondTimingReferenceType |
type=sonet.ReferenceType default=port Displayed(tab/group)=Type (/Timing Reference Two) |
| secondarySyncProtectionUnitCriteria |
type=sonet.SyncProtectionUnitCriteria Displayed(tab/group)=Secondary Criteria (/Synchronization Protection) |
| secondarySyncProtectionUnitStatus |
type=mpr.SwitchStatus Displayed(tab/group)=Secondary Status (/Synchronization Protection) |
| secondaryTimingReferenceType |
type=sonet.MprSyncReferenceType default=freeRunLocalOscillator Displayed(tab/group)=Secondary Reference Type (/Reference Type) |
| shelfId |
type=int access=read-only default=1 |
| siteId |
Specifies the SiteId of the node
type=string Displayed(tab/group)=Site Id |
| sixthTimingReferenceInput |
type=sonet.TimingSourcePreference default=gnss Displayed(tab/group)=Sixth Timing Reference Input (/Reference Order) |
| sonet.PtpClock-Set |
type=Children-Set |
| sonet.PtpPort-Set |
type=Children-Set |
| sonet.SyncCommitter-Set |
type=Children-Set |
| sonet.TransactionObject-Set |
type=Children-Set |
| status |
type=sonet.TimingStatus access=read-only Displayed(tab/group)=Status |
| syncE2AdministrativeState |
The value of SyncE2AdmnStatus indicates the
administrative status of the Synchronous Ethernet (SyncE) timing
reference.
type=sonet.AdministrativeState default=down |
| syncE2Alarms |
The value of SyncE2Alarm indicates the alarms on the
Synchronous Ethernet (SyncE2) reference. If any of the bits is set to '1',
then the SyncE2 reference is disqualified by the timing subsystem and the value of
SyncE2Qualified is set to 'not-qualified'.
los - loss of signal
oof - out of frequency range
oopir - out of pull in range
type=sonet.ProblemCode access=read-only default=0 |
| syncE2InUse |
The value of SyncE2InUse indicates whether the Synchronous
Ethernet (SyncE) timing reference is presently being used by the synchronous
timing subsystem. If it is in use, FreqOffset indicates
the frequency offset for this reference.
type=generic.TruthValue access=read-only default=false |
| syncE2Qualified |
The value of SyncE2Qualified indicates whether the Synchronous
Ethernet (SyncE) timing reference is qualified for use by the synchronous timing
subsystem. If SyncE2Qualified is set to 'not-qualified',
then the object SyncEAlarm gives the reason for
disqualification.
type=sonet.TimingReferenceQualified access=read-only default=0 |
| syncE2QualityLevel |
The value of syncE2QualityLevel indicates the configured
Quality Level of the Synchronous Ethernet (SyncE) timing reference. A
value of 'unknown (0)' indicates SyncE is not forced to a specific
quality level.
type=sonet.SystemQualityLevelType default=unknown |
| syncE2State |
The value of syncE2State indicates the operational
state of the Synchronous Ethernet (SyncE) timing reference.
type=sonet.PtpInState access=read-only |
| syncE2TimingReferenceRxQltyLevel |
The value of syncE2TimingReferenceRxQltyLevel indicates the received
SSM Quality Level of the Synchronous Ethernet (SyncE) timing
reference
type=sonet.SystemQualityLevelType access=read-only |
| syncEAdministrativeState |
The value of SyncEAdmnStatus indicates the
administrative status of the Synchronous Ethernet (SyncE) timing
reference.
type=sonet.AdministrativeState default=down Displayed(tab/group)=Administrative State (/SyncE) |
| syncEAlarms |
The value of SyncEAlarm indicates the alarms on the
Synchronous Ethernet (SyncE) reference. If any of the bits is set to '1',
then the SyncE reference is disqualified by the timing subsystem and the value of
SyncEQualified is set to 'not-qualified'.
los - loss of signal
oof - out of frequency range
oopir - out of pull in range
type=sonet.ProblemCode access=read-only default=0 Displayed(tab/group)=Not Qualified Due To (/SyncE) |
| syncEInUse |
The value of SyncEInUse indicates whether the Synchronous
Ethernet (SyncE) timing reference is presently being used by the synchronous
timing subsystem. If it is in use, FreqOffset indicates
the frequency offset for this reference.
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Selected For Use (/SyncE) |
| syncEQualified |
The value of SyncEQualified indicates whether the Synchronous
Ethernet (SyncE) timing reference is qualified for use by the synchronous timing
subsystem. If SyncEQualified is set to 'not-qualified',
then the object SyncEAlarm gives the reason for
disqualification.
type=sonet.TimingReferenceQualified access=read-only default=0 Displayed(tab/group)=Qualified For Use (/SyncE) |
| syncEQualityLevel |
The value of syncEQualityLevel indicates the configured
Quality Level of the Synchronous Ethernet (SyncE) timing reference. A
value of 'unknown (0)' indicates SyncE is not forced to a specific
quality level.
type=sonet.SystemQualityLevelType default=unknown Displayed(tab/group)=Quality Level Override (/SyncE) |
| syncEState |
The value of syncEState indicates the operational
state of the Synchronous Ethernet (SyncE) timing reference.
type=sonet.PtpInState access=read-only Displayed(tab/group)=Not Selected Due To (/SyncE) |
| syncETimingReferenceRxQltyLevel |
The value of syncETimingReferenceRxQltyLevel indicates the received
SSM Quality Level of the Synchronous Ethernet (SyncE) timing
reference
type=sonet.SystemQualityLevelType access=read-only Displayed(tab/group)=Received Quality Level (/SyncE) |
| syncInPort |
type=sonet.SynchronizationType default=notUsed |
| syncInTimingReferencePortName |
type=string default= maximum=252 |
| syncInTimingReferencePortPointer |
type=Pointer default= Displayed(tab/group)=Timing Reference (/Sync In) |
| syncInTimingReferencePortSnmpId |
type=long access=read-only default=0 |
| syncOutPort |
type=sonet.SynchronizationType default=notUsed |
| syncPhysicalInterfaceIndex |
type=int access=read-only default=0 |
| syncPhysicalInterfaceType |
type=int default=1 |
| syncProtectionGroupIndex |
type=int access=read-only default=0 |
| syncProtectionUnitIndex |
type=int access=read-only default=0 |
| syncProtectionUnitPriority |
type=int default=1 |
| syncProtectionUnitRowStatus |
type=mpr.RowStatus default=destroy |
| syncProtectionUnitSwitchCriteria |
type=sonet.SyncProtectionUnitCriteria default=0 |
| syncProtectionUnitSwitchStatus |
type=mpr.SwitchStatus default=0 |
| synce.TimeSyncLink-Set |
type=Children-Set |
| systemQualityLevel |
type=sonet.SystemQualityLevelType access=read-only Displayed(tab/group)=System Quality Level |
| thirdTimingReferenceInput |
type=sonet.TimingSourcePreference default=referenceTwo Displayed(tab/group)=Third Timing Reference Input (/Reference Order) |
| ubtStandaloneType |
This attribute is applicable just for Wavence UBT-SA node and identifies the type of UBT configured.
type=int access=read-only default=0 |
| waitToRestore |
The value specifies the time, in minutes, that a previously failed input reference must be valid before
it will be used for either the BITS output or the central clock input reference.
type=int default=0 minimum=0 maximum=12 Displayed(tab/group)=Wait To Restore |
| waitToRestoreMin |
type=int default=0 minimum=0 maximum=12 units=Min Displayed(tab/group)=Wait to Restore Time in Min (/Wait To Restore Time) |
| waitToRestoreSec |
type=int default=0 units=Secs Displayed(tab/group)=Wait to Restore Time in Sec (/Wait To Restore Time) enums= 0: 0 - 0 10: 10 - 10 20: 20 - 20 30: 30 - 30 40: 40 - 40 50: 50 - 50 |
| waitToRestoreTime |
type=int access=read-only default=0 |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |
| Methods |
|---|
aInFilter
: FilterHolder -
resultFilter
: ResultFilter - (Optional) Filter for narrowing down the information returned per object
continueOnFailure
: continueOnFailure - (Optional) Continue processing requests in this stream if an exception occurs, unless the request is invalid. Default: false
result
: generic.PagingResult -
aInSiteId
: string -
aInFilter
: FilterHolder -
resultFilter
: ResultFilter - (Optional) Filter for narrowing down the information returned per object
continueOnFailure
: continueOnFailure - (Optional) Continue processing requests in this stream if an exception occurs, unless the request is invalid. Default: false
result
: generic.PagingResult -
networkElementList
: Set (Pointer) - The set of NE's on the physical topology
continueOnFailure
: continueOnFailure - (Optional) Continue processing requests in this stream if an exception occurs, unless the request is invalid. Default: false
result
: Map (string to int) - Map that holds the fdn of the network element this SiteSync is on
and its state (i.e. if either it should categorized as Red/Yellow/Green)