service
Y1564FrameMixProfile

This class is used to configure Frame Mix parameters for Y1564 Test.



public class Y1564FrameMixProfile

Properties
runningInstance Specifies the instance of Frame Mix profile used in service test.

type=long
access=read-only
default=1

sizeA Specifies the Ethernet frame size to be associated with the letter A. The default values are defined in ITU-T Y.1564. You can configure a custom value within the applicable range. The frame sizes used in a test are defined by configuring the required letters in the Frame Mix Sequence parameter on the Y1564 Service Test Stream (Y1564ServiceTestStream) form.

type=int
default=64
minimum=64
maximum=9212
Displayed(tab/group)=Size A

sizeB Specifies the Ethernet frame size to be associated with the letter B. The default values are defined in ITU-T Y.1564. You can configure a custom value within the applicable range. The frame sizes used in a test are defined by configuring the required letters in the Frame Mix Sequence parameter on the Y1564 Service Test Stream (Y1564ServiceTestStream) form.

type=int
default=128
minimum=64
maximum=9212
Displayed(tab/group)=Size B

sizeC Specifies the Ethernet frame size to be associated with the letter C. The default values are defined in ITU-T Y.1564. You can configure a custom value within the applicable range. The frame sizes used in a test are defined by configuring the required letters in the Frame Mix Sequence parameter on the Y1564 Service Test Stream (Y1564ServiceTestStream) form.

type=int
default=256
minimum=64
maximum=9212
Displayed(tab/group)=Size C

sizeD Specifies the Ethernet frame size to be associated with the letter D. The default values are defined in ITU-T Y.1564. You can configure a custom value within the applicable range. The frame sizes used in a test are defined by configuring the required letters in the Frame Mix Sequence parameter on the Y1564 Service Test Stream (Y1564ServiceTestStream) form.

type=int
default=512
minimum=64
maximum=9212
Displayed(tab/group)=Size D

sizeE Specifies the Ethernet frame size to be associated with the letter E. The default values are defined in ITU-T Y.1564. You can configure a custom value within the applicable range. The frame sizes used in a test are defined by configuring the required letters in the Frame Mix Sequence parameter on the Y1564 Service Test Stream (Y1564ServiceTestStream) form.

type=int
default=1024
minimum=64
maximum=9212
Displayed(tab/group)=Size E

sizeF Specifies the Ethernet frame size to be associated with the letter F. The default values are defined in ITU-T Y.1564. You can configure a custom value within the applicable range. The frame sizes used in a test are defined by configuring the required letters in the Frame Mix Sequence parameter on the Y1564 Service Test Stream (Y1564ServiceTestStream) form.

type=int
default=1280
minimum=64
maximum=9212
Displayed(tab/group)=Size F

sizeG Specifies the Ethernet frame size to be associated with the letter G. The default values are defined in ITU-T Y.1564. You can configure a custom value within the applicable range. The frame sizes used in a test are defined by configuring the required letters in the Frame Mix Sequence parameter on the Y1564 Service Test Stream (Y1564ServiceTestStream) form.

type=int
default=1518
minimum=64
maximum=9212
Displayed(tab/group)=Size G

sizeH Specifies the Ethernet frame size to be associated with the letter H. The default values are defined in ITU-T Y.1564. You can configure a custom value within the applicable range. The frame sizes used in a test are defined by configuring the required letters in the Frame Mix Sequence parameter on the Y1564 Service Test Stream (Y1564ServiceTestStream) form.

type=int
default=9212
minimum=64
maximum=9212
Displayed(tab/group)=Size H

sizeU Specifies the Ethernet frame size to be associated with the letter U. The default values are defined in ITU-T Y.1564. You can configure a custom value within the applicable range. The frame sizes used in a test are defined by configuring the required letters in the Frame Mix Sequence parameter on the Y1564 Service Test Stream (Y1564ServiceTestStream) form.

type=int
default=0
minimum=0
maximum=9212
Displayed(tab/group)=Size U

 
Overridden Properties
id Specifies an ID number for the Frame Mix configuration

minimum=1
maximum=1000

 
Properties inherited from policy.PolicyDefinition
configurationAction, configurationMode, discoveryState, displayedName, distributionMode, isMaster, lastSyncTime, numberOfUnderlyingPolicyItems, origin, policyMode, policySyncGroupPointer, policyType
 
Properties inherited from policy.PolicyObject
description, displayedName, globalPolicy, id, isLocal, policyType, siteId, siteName, templateObject
 
Properties inherited from ManagedObject
actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed
 
Methods

findTests

Input Parameters:
instanceFullName : string - the full name of the object.
filter : FilterHolder -
resultFilter : ResultFilter - (Optional) Filter for narrowing down the information returned per object
continueOnFailure : continueOnFailure - (Optional) Continue processing requests in this stream if an exception occurs, unless the request is invalid. Default: false
Output Parameters:
infoList : List (generic.CommonManagedEntityInformation) -
Methods inherited from policy.PolicyDefinition
distribute, distributeUsingGroups, distributeV2, evaluatePolicy, findGlobal, findLocal, findReleased, getSyncTaskResult, resetToReleasedPolicy, setConfigurationModeToDraft, setConfigurationModeToReleased, setDistributionModeToLocalEditOnly, setDistributionModeToSyncWithGlobal, syncTo, syncToLocalWithResync
 
Supported Network Elements
7210 SAS K Supported from 10.0.R3
Product Specifics
7210 SAS K (all versions)