PtpPerformanceMonitoringStatsLogRecord



public class PtpPerformanceMonitoringStatsLogRecord

Stats For:
ptp.IEEEPTPClock

Properties
ptpPerfMonAvgMastSlavDly It is the average of the master-slave delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonAvgMeanPathDly It is the average of the mean path delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonAvgOffsetFrMaster It is the average of the offset from master for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonAvgSlavMastDly It is the average of the slave-master delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonDuration Indicates the amount of time, in seconds, for which the data for this record was collected.

type=int
access=read-only
units=seconds

ptpPerfMonIndex Gives the index to each record in the list. Values supported are: 0 :current 15 minute interval, 1..96 :previous 15 minute intervals (1 being the most recent), 97 :current 24 hour interval, 98 :previous 24 hour interval, 501 :current 1 minute interval, 502..516 :previous 1 minute intervals (502 being the most recent)

type=int
access=read-only
minimum=0
maximum=516

ptpPerfMonIndexPeriodic Gives the index to each record in the list. Values supported are: 0 :current 15 minute interval, 1..96 :previous 15 minute intervals (1 being the most recent), 97 :current 24 hour interval, 98 :previous 24 hour interval, 501 :current 1 minute interval, 502..516 :previous 1 minute intervals (502 being the most recent)

type=int
access=read-only
minimum=0
maximum=516

ptpPerfMonMaxMastSlavDly It is the maximum of the master-slave delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonMaxMeanPathDly It is the maximum of the mean path delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonMaxOffsetFrMaster It is the maximum of the offset from master for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonMaxSlavMastDly It is the maximum of the slave-master delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonMeasureValid Indicates the data can be correctly interpreted. For example, if for some periods the data is not valid for part of the data collection interval (e.g. the clock is not locked), ptpPerfMonMeasureValid will be set to false. This flag applies to all parameters for a given measurement period.

type=boolean
access=read-only
default=false

ptpPerfMonMinMastSlavDly It is the minimum of the master-slave delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonMinMeanPathDly It is the minimum of the mean path delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonMinOffsetFrMaster It is the minimum of the offset from master for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonMinSlavMastDly It is the minimum of the slave-master delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonPeriodComplete It is set to true when the recording period closes and measurements were performed during the entire period (1 minute, 15 minute, or 24 hour). For example, if the PTP instance is disabled for 5 minutes of a 15 minute period, ptpPerfMonPeriodComplete is false. The ptpPerfMonPeriodComplete flag is not related to the validity of measurements that were performed. This flag applies to all parameters for a given measurement period. A recording period closes at the next boundary for the record type 15 minute:0, 15, 30, 45 minutes after the hour. UTC. 24 hour:00:00. UTC. 1 minute:integral minute. UTC.

type=boolean
access=read-only
default=false

ptpPerfMonSDevMastSlavDly It is the standard deviation of the master-slave delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonSDevMeanPathDly It is the standard deviation of the mean path delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonSDevOffsetFrMaster It is the standard deviation of the offset from master for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonSDevSlavMastDly It is the standard deviation of the slave-master delay for this interval. An invalid value (not measured correctly) shall be indicated with one in all bits, except the most significant.

type=string
access=read-only
units=ns

ptpPerfMonStartTime Indicates the time of the beginning of the measurement record.

type=string
access=read-only
units=UTC

  
Properties inherited from log.LogRecord
createdOnPollType, displayedName, monitoredObjectClass, monitoredObjectPointer, monitoredObjectSiteId, monitoredObjectSiteName, periodicTime, suspect, timeCaptured, timeLogged, updatedOnPollType
 
Properties inherited from ManagedObject
actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed
 