Properties |
|
ptpPerfMonAvgMastSlavDly |
It is the average of the master-slave delay for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonAvgMeanPathDly |
It is the average of the mean path delay for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonAvgOffsetFrMaster |
It is the average of the offset from master for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonAvgSlavMastDly |
It is the average of the slave-master delay for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonDuration |
Indicates the amount of time, in seconds, for which the data for this record was collected.
type=int
access=read-only units=seconds
|
|
ptpPerfMonIndex |
Gives the index to each record in the list. Values supported are:
0 :current 15 minute interval, 1..96 :previous 15 minute intervals (1 being the most recent),
97 :current 24 hour interval, 98 :previous 24 hour interval, 501 :current 1 minute interval,
502..516 :previous 1 minute intervals (502 being the most recent)
type=int
access=read-only minimum=0 maximum=516
|
|
ptpPerfMonIndexPeriodic |
Gives the index to each record in the list. Values supported are:
0 :current 15 minute interval, 1..96 :previous 15 minute intervals (1 being the most recent),
97 :current 24 hour interval, 98 :previous 24 hour interval, 501 :current 1 minute interval,
502..516 :previous 1 minute intervals (502 being the most recent)
type=int
access=read-only minimum=0 maximum=516
|
|
ptpPerfMonMaxMastSlavDly |
It is the maximum of the master-slave delay for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonMaxMeanPathDly |
It is the maximum of the mean path delay for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonMaxOffsetFrMaster |
It is the maximum of the offset from master for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonMaxSlavMastDly |
It is the maximum of the slave-master delay for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonMeasureValid |
Indicates the data can be correctly interpreted. For example, if for some periods the data is
not valid for part of the data collection interval (e.g. the clock is not locked), ptpPerfMonMeasureValid
will be set to false. This flag applies to all parameters for a given measurement period.
type=boolean
access=read-only default=false
|
|
ptpPerfMonMinMastSlavDly |
It is the minimum of the master-slave delay for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonMinMeanPathDly |
It is the minimum of the mean path delay for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonMinOffsetFrMaster |
It is the minimum of the offset from master for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonMinSlavMastDly |
It is the minimum of the slave-master delay for this interval. An invalid value (not measured
correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonPeriodComplete |
It is set to true when the recording period closes and measurements were performed during the entire period
(1 minute, 15 minute, or 24 hour). For example, if the PTP instance is disabled for 5 minutes of a 15 minute
period, ptpPerfMonPeriodComplete is false. The ptpPerfMonPeriodComplete flag is not related to the validity
of measurements that were performed. This flag applies to all parameters for a given measurement period. A
recording period closes at the next boundary for the record type 15 minute:0, 15, 30, 45 minutes after the
hour. UTC. 24 hour:00:00. UTC. 1 minute:integral minute. UTC.
type=boolean
access=read-only default=false
|
|
ptpPerfMonSDevMastSlavDly |
It is the standard deviation of the master-slave delay for this interval. An invalid value (not
measured correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonSDevMeanPathDly |
It is the standard deviation of the mean path delay for this interval. An invalid value (not
measured correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonSDevOffsetFrMaster |
It is the standard deviation of the offset from master for this interval. An invalid value (not
measured correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonSDevSlavMastDly |
It is the standard deviation of the slave-master delay for this interval. An invalid value (not
measured correctly) shall be indicated with one in all bits, except the most significant.
type=string
access=read-only units=ns
|
|
ptpPerfMonStartTime |
Indicates the time of the beginning of the measurement record.
type=string