| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| chliThreshold |
Specifies the MEF-35 Consecutive High Loss Intervals (CHLI) threshold for the specified session's SLM test.
An attempt to change ChliThreshold to a value greater than or equal to tmnxOamPmCfgLossSlmConsecDeltaTs will be rejected.
type=int default=5 minimum=1 maximum=9 Displayed(tab/group)=CHLI Threshold (/Timing) |
| consecDeltaTs |
Specifies the number of consecutive MEF-35 'delta_t's (also known as 'Small Time Intervals') which constitute a MEF-35 'Availability Window.
type=int default=10 minimum=2 maximum=10 Displayed(tab/group)=Consec Delta-T's (/Timing) |
| flrThreshold |
Specifies the MEF-35 Frame Loss Ratio (FLR) threshold for the specified session's SLM test.
The FLR threshold is used to decide if a MEF-35 Small Time Interval (also known as delta_t) is Available or Unavailable.
type=int default=50 minimum=0 maximum=100 units=percent Displayed(tab/group)=flr Threshold (/Test Details) |
| hliForceCountEnabled |
Specifies whether or not
to count High Loss Intervals (HLIs) and Consecutive High Loss
Intervals (CHLIs) when the SLM test's MEF-35 Availability state is
Unavailable.
'true(1)' breaks compliance with MEF-35 by ensuring HLIs and CHLIs are
counted in Unavailable periods.
'false(2)' maintains compliance with MEF-35 by preventing HLIs and
CHLIs from being counted in Unavailable periods.
type=boolean default=false Displayed(tab/group)=HLI Force Count (/Timing) |
| interval |
Specifies the elapsed time between transmission of Y.1731 PDUs for the specified session's CFM test.
Valid values (50 | 100 | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 900 | 1000).
type=ethernetoam.SessionInterval default=100 minimum=50 maximum=1000 Displayed(tab/group)=Interval (/Timing) |
| sas.LossTCAConfigDefinition-Set |
type=Children-Set |
| trapsEnabled |
The value of tmnxOamPmCfgLossSlmTrapsEnabled specifies the set of traps to be enabled for the specified session's SLM test.
DEPRECATED: 13.0R1 - OBSOLETE: Never used type=ethernetoam.SlmTrapsEnabled |
| txFrmsPerDelT |
The value of tmnxOamPmCfgLossSlmTxFrmsPerDelT specifies the number of Y.1731 SLM frames to send in one MEF-35 'delta_t' (also known as 'Small Time Interval') for the specified session's SLM test.
Expressed in milliseconds,
delta_t =tmnxOamPmCfgLossSlmTxFrmsPerDelT*tmnxOamPmCfgLossSlmInterval.
type=int default=10 minimum=1 maximum=50 units=packets Displayed(tab/group)=Frames Per Delta-T (/Timing) |
| Properties inherited from ethernetoam.AbstractCfmSessionDefinition |
|---|
| dataTlvSize |
| Properties inherited from sas.PMSessionTestDefinition |
|---|
| administrativeState, publishTopic, testDefinitionmodified, writeAccountingResultsToDb |
| Properties inherited from sas.AbstractTest |
|---|
| administrativeState, description, displayedName, failures, globalId, id, lastRunResult, runs, weight |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |
| Methods inherited from sas.AbstractTest |
|---|
| execute, stop |