| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| disableSHCV |
Defines whether or not the node will suspend SHCV for the hosts defined with this ANCP Policy.
type=generic.TruthValue default=false Displayed(tab/group)=Disable SHCV (/Port Down) |
| disableSHCVHoldTime |
Defines how long SHCV is suspended until the access node sends a port-up message.
type=long default=0 minimum=0 maximum=7200 units=seconds Displayed(tab/group)=Disable SHCV Hold Time (/Port Down) |
| disableSHCVNtf |
Defines whether or not the system should generate a notification before suspending SHCV on
the node.
type=generic.TruthValue default=false Displayed(tab/group)=Disable SHCV Notification (/Port Down) |
| egrRateAdjustment |
Defines the rate adjustment for the Egress Scheduler.
type=long default=100 minimum=1 maximum=200 units=% Displayed(tab/group)=Rate Adjustment (/Egress) |
| egrRateModSchedObjPointer |
Defines the scheduler to be applied for egress-rate modification.
type=string default= minimum=0 maximum=32 Displayed(tab/group)=Rate Modification Scheduler (/Egress) |
| egrRateModificationType |
Defines the Egress-rate modification that is to be applied.
type=ancp.EgrModificationTypes default=none Displayed(tab/group)=Rate Modification (/Egress) |
| egrRateMonitor |
Defines the rate below which the system will generate an event.
type=long default=0 minimum=0 maximum=4294967295 units=kbps Displayed(tab/group)=Rate Monitor (/Egress) |
| egrRateMonitorNtf |
Defines whether the system will generate an event if the rate goes below a certain threshold.
type=generic.TruthValue default=false Displayed(tab/group)=Rate Monitor Notification (/Egress) |
| egrRateReduction |
Defines the constant rate reduction for the Egress Scheduler.
type=long default=0 minimum=0 maximum=4294967295 units=kbps Displayed(tab/group)=Rate Reduction (/Egress) |
| ingRateAdjustment |
Defines the rate adjustment for the Ingress Scheduler.
type=long default=100 minimum=1 maximum=200 units=% Displayed(tab/group)=Rate Adjustment (/Ingress) |
| ingRateModSchedObjPointer |
Defines the scheduler to be applied for ingress-rate modification.
type=string default= minimum=0 maximum=32 Displayed(tab/group)=Rate Modification Scheduler (/Ingress) |
| ingRateModificationType |
Defines the Ingress-rate modification that is to be applied.
type=ancp.IngModificationTypes default=none Displayed(tab/group)=Rate Modification (/Ingress) |
| ingRateMonitor |
Defines the rate below which the system will generate an event.
type=long default=0 minimum=0 maximum=4294967295 units=kbps Displayed(tab/group)=Rate Monitor (/Ingress) |
| ingRateMonitorNtf |
Defines whether the system will generate an event if the rate goes below a certain threshold.
type=generic.TruthValue default=false Displayed(tab/group)=Rate Monitor Notification (/Ingress) |
| ingRateReduction |
Defines the constant rate reduction for the Ingress Scheduler.
type=long default=0 minimum=0 maximum=4294967295 units=kbps Displayed(tab/group)=Rate Reduction (/Ingress) |
| Overridden Properties | |
|---|---|
| displayedName |
Unique Ancp Policy name
access=read-create minimum=1 maximum=32 |
| Properties inherited from policy.PolicyObject |
|---|
| description, displayedName, globalPolicy, id, isLocal, policyType, siteId, siteName, templateObject |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |
| Supported Network Elements | |
|---|---|
| 7750 SR | |
| 7705 SAR Hm | |
| 7450 ESS | |