| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| activate |
"Activate."
type=generic.TruthValue default=false Displayed(tab/group)=Activate (OPS PSE-R protection switch management) |
| actualSwitchCount |
"Actual number of switch counts."
type=long access=read-only minimum=0 maximum=65535 Displayed(tab/group)=Actual Switch Count (OPS PSE-R protection switch management) |
| bounceTimer |
"Protection switch bounce timer."
type=long default=0 minimum=0 maximum=65535 units=ms Displayed(tab/group)=Bounce Timer (OPS PSE-R protection switch management) |
| description |
"Description of the OSM PSE-R protection switch instance."
type=string default= maximum=64 Displayed(tab/group)=Description (OPS PSE-R protection switch management) |
| externalCommand |
"Protection switch external command."
type=string access=read-only Displayed(tab/group)=External Command (OPS PSE-R protection switch management) |
| holdOffTimer |
"Hold-off timer for the OPR defects on the monitor loops."
type=long minimum=0 maximum=65535 units=ms Displayed(tab/group)=Hold Off Timer (OPS PSE-R protection switch management) |
| isRevertive |
"Whether the OPS OSM PSE-R Entity should try to restore selection of the working leg."
type=generic.TruthValue default=false Displayed(tab/group)=Is Revertive (OPS PSE-R protection switch management) |
| loopDefectForwordingStatus |
"Enable or disable the defect forwarding for the worker and protection loops."
type=generic.EnabledDisabled default=enabled Displayed(tab/group)=Loop Defect Fwd Status (OPS PSE-R protection switch management) |
| maximumSwitchCount |
"Maximum number of switch counts."
type=long default=30 minimum=1 maximum=65535 Displayed(tab/group)=Maximum Switch Count (OPS PSE-R protection switch management) |
| pmuDLine1IsWorker |
"Indicates whether the LINE1 interface of the PMU-D, see object tnVwmMsOpsOsmPserPmudShelfIndex, is used to monitor the worker loop or not.
The LINE2 interface of the PMU-D is implicitly used to monitor the other loop."
type=generic.TruthValue default=true Displayed(tab/group)=PMUD Line 1 Worker Status (OPS PSE-R protection switch management) |
| pmudGroup |
"Description of the OSM PSE-R protection switch instance."
type=Pointer default= Displayed(tab/group)=PMUD Group (OPS PSE-R protection switch management) |
| pmudSelectorPosition |
"The actual position of the PMU-D BAND selector."
type=vwm.PmudSelectorPosition access=read-only Displayed(tab/group)=PMU D selected Band (OPS PSE-R protection switch management) |
| pmudShelfIndex |
I
"Indicates the PMU-D of which the LINE ports participate in the protection group."
type=Pointer Displayed(tab/group)=PMU D Shelf Index (OPS PSE-R protection switch management) |
| pmudTRMTBand1DefectStatus |
"Optical Transmit Power (TRMT) defect status of the PMU-D BAND1 interface."
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=TRMT Band 1 Defect Status (OPS PSE-R protection switch management) |
| pmudTRMTBand2DefectStatus |
"Optical Transmit Power (TRMT) defect status of the PMU-D BAND2 interface."
type=generic.TruthValue access=read-only Displayed(tab/group)=TRMT Band 2 Defect Status (OPS PSE-R protection switch management) |
| protectionSignalFailStatus |
"Signal-Fail (SF) status on the protection monitor loop."
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Protection Signal Fail Status (OPS PSE-R protection switch management) |
| pseRAvailabilityStatus |
"Indicates the availability of the read-only data of the current row."
type=vwm.VwmMsInventoryStatus access=read-only default=unavailable Displayed(tab/group)=Availability Status (OPS PSE-R protection switch management) |
| pseRClearWtrTimer |
"Force expiry of the Wait-to-Restore timer by writing to this object.
If set to true(1) the Wait-to-Restore timer is expired. If set to false(2) no action is taken.
If set to true(1) the Wait-to-Restore timer is expired. If set to false(2) no action is taken.
Reading this object always returns false(2)."
type=generic.TruthValue default=true Displayed(tab/group)=Clear Wait-to-Restore Timer (OPS PSE-R protection switch management) |
| pseRWtrTimer |
"The Wait-to-Restore timer value."
type=int default=10 minimum=0 maximum=60 units=minutes Displayed(tab/group)=Wait-to-Restore Timer (OPS PSE-R protection switch management) |
| pseRWtrTimerRemain |
"The Wait-to-Restore timer remaining time."
type=long access=read-only minimum=0 maximum=65535 Displayed(tab/group)=Wait-to-Restore Timer Remaning (OPS PSE-R protection switch management) |
| resetSwitchCount |
"Writing true(1) to this object resets the switch count of the protection switch. Writing false(2) is a NOP.
Reading this object always returns false(2)."
type=generic.TruthValue default=false Displayed(tab/group)=Reset Switch Count (OPS PSE-R protection switch management) |
| resetTimer |
"Protection switch count reset timer."
type=long default=900000 minimum=1 maximum=4294967295 units=ms Displayed(tab/group)=Reset Timer (OPS PSE-R protection switch management) |
| rxPos |
"RX selector position. Possible values are A and B."
type=string access=read-only Displayed(tab/group)=RX selector position (OPS PSE-R protection switch management) |
| shelfId |
shelf identifier
type=int default=1 minimum=1 maximum=2047 |
| siteId |
type=string access=read-only default= maximum=64 |
| slotId |
slot identifier
type=int default=1 minimum=1 maximum=255 |
| slotPointer |
slot A Pointer.
type=Pointer access=read-create default= Mandatory on create Displayed(tab/group)=Slot (OPS PSE-R protection switch management) |
| state |
Protection switch status.
type=string access=read-only Displayed(tab/group)=Switch Status (OPS PSE-R protection switch management) |
| switchCommand |
"User configurable protection switch command."
type=vwm.OpsOsmSwitchCommand Displayed(tab/group)=Switch Command (OPS PSE-R protection switch management) |
| txPos |
"TX selector position. Possible values are A and B."
type=string access=read-only Displayed(tab/group)=TX selector position (OPS PSE-R protection switch management) |
| workerSignalFailStatus |
"Signal-Fail (SF) status on the worker monitor loop."
type=generic.TruthValue access=read-only default=false Displayed(tab/group)=Worker Signal Fail Status (OPS PSE-R protection switch management) |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |
| Supported Network Elements | |
|---|---|
| 1830 VWM OSU | Supported from 8.5.0 |