| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| activate |
"Activate."
type=generic.TruthValue default=false Displayed(tab/group)=Activate (/OPS Protection Audit Entity) |
| paeClearWtrTimer |
"Force expiry of the Wait-to-Restore timer by writing to this object.
If set to true(1) the Wait-to-Restore timer is expired. If set to false(2) no action is taken.
Reading this object always returns false(2)."
type=generic.TruthValue default=false Displayed(tab/group)=Clear Wait-to-Restore Timer (/OPS Protection Audit Entity) |
| paeDescription |
"Description of the OPS Protection Audit Entity."
type=string minimum=0 maximum=64 Displayed(tab/group)=PAE Description (/OPS Protection Audit Entity) |
| paeRevertive |
"Whether the OPS Protection Audit Entity should try to restore selection of the working leg.
If set to true(1) and the working leg is found to be in order, after expiry of the Wait-to-Restore timer, both OPS's revert to the working leg.
If set to false(2) the OPS's retain the selected leg."
type=generic.TruthValue default=false Displayed(tab/group)=Revertive (/OPS Protection Audit Entity) |
| paeStatus |
"The status of the OPS Protection Audit Entity."
type=vwm.OpsPaeStatus Displayed(tab/group)=PAE Status (/OPS Protection Audit Entity) |
| paeWtrTimer |
"The Wait-to-Restore timer value."
type=int default=10 minimum=0 maximum=60 units=minutes Displayed(tab/group)=Wait-to-Restore Timer (/OPS Protection Audit Entity) |
| paeWtrTimerRemain |
"The Wait-to-Restore timer remaining time."
type=long access=read-only minimum=0 maximum=65535 Displayed(tab/group)=Wait-to-Restore Timer Remain (/OPS Protection Audit Entity) |
| shelfAId |
"OPS A shelf index number."
type=int default=1 minimum=1 maximum=2047 |
| shelfZId |
"OPS Z shelf index number."
type=int default=1 minimum=1 maximum=2047 |
| siteId |
type=string access=read-only default= maximum=64 |
| slotAId |
"OPS A slot index number."
type=int default=1 minimum=1 maximum=255 |
| slotAPointer |
slot A Pointer.
type=Pointer access=read-create default= Mandatory on create Displayed(tab/group)=Slot A (/OPS Protection Audit Entity) |
| slotZId |
"OPS A slot index number."
type=int default=1 minimum=1 maximum=255 |
| slotZPointer |
slot A Pointer.
type=Pointer access=read-create default= Mandatory on create Displayed(tab/group)=Slot Z (/OPS Protection Audit Entity) |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |
| Supported Network Elements | |
|---|---|
| 1830 VWM OSU | Supported from 8.3.0 |
| Product Specifics | |
| 1830 VWM OSU 8.3 | |
| 1830 VWM OSU 8.4 | |
| 1830 VWM OSU 8.5 | |
| 1830 VWM OSU 9.0 | |