vwm
IfPcsHistoryStatsLogRecord

Pcs Statistics



public class IfPcsHistoryStatsLogRecord

Stats For:
equipment.PhysicalPort

Properties
binId

type=int
access=read-only
default=0

elapsedTime

type=long
access=read-only
default=0

endTime The NE's bin collection end date and time

type=string
access=read-only
default=unknown

ifPcsHistoryStatsIfCv "Number of code violations in the measurement interval."

type=long
access=read-only
default=0

ifPcsHistoryStatsIfEs "Number of errored seconds in the measurement interval."

type=long
access=read-only
default=0

ifPcsHistoryStatsIfSefs "Number of severely errored frame seconds in the measurement interval."

type=long
access=read-only
default=0

ifPcsHistoryStatsIfSes "Number of severely errored seconds in the measurement interval."

type=long
access=read-only
default=0

interval

type=vwm.IntervalType
access=read-only
default=0

suspectStatus

type=vwm.SuspectStatus
access=read-only
default=1

timeRecorded The NE's bin collection start date and time

type=Date
access=read-only
default=0

  
Properties inherited from log.LogRecord
createdOnPollType, displayedName, monitoredObjectClass, monitoredObjectPointer, monitoredObjectSiteId, monitoredObjectSiteName, periodicTime, suspect, timeCaptured, timeLogged, updatedOnPollType
 
Properties inherited from ManagedObject
actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed
 
Supported Network Elements
1830 VWM OSU Supported from 8.4.0