sas
WavenceLossTCAConfig



public class WavenceLossTCAConfig

Properties
direction The value of 'direction' specifies the direction of the row to be configured or read

type=sas.ForwardBackwardAggrType
access=read-create
Mandatory on create
Displayed(tab/group)=Direction

flrClear The value of clear specifies the clear threshold for the average Frame Loss Ratio (FLR).

type=float
default=-1
minimum=-1
maximum=99.999
units=%
Displayed(tab/group)=FLR Clear

flrRaise The value of raise specifies the raise threshold for the average Frame Loss Ratio (FLR).

type=float
default=-1
minimum=-1
maximum=100
units=%
Displayed(tab/group)=FLR Raise

intervalDuration

type=sas.MeasurementIntervalDurationConfig
access=read-create
default=15min
Displayed(tab/group)=Interval Duration

sessionName

type=string
access=read-only
default=
maximum=32

testType

type=sas.PMTestType
access=read-only

  
Properties inherited from ManagedObject
actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed
 
Supported Network Elements