rtr
StaticPolicySRv6BindingSID

This class represents a configuration for segment routing v6 for a virtual router in the system.



public class StaticPolicySRv6BindingSID

Properties
bindingSidAddress Specifies the binding SID for a non-local SRv6 policy. bindingSidAddress must be configured if the head-end of the policy is not the local node. Binding SID address and locator can't be both configured at the same time.

type=InetAddress
default=0:0:0:0:0:0:0:0
Displayed(tab/group)=IP Address

bindingSidAddressType Specifies the type of the binding SID address. Binding SID address and locator can't be both configured at the same time.

type=rtr.InetAddressType
default=unknown

bindingSidId Specifies the index of binding SID. Only one binding SID is supported at this time.

type=int
access=read-create
default=1
minimum=0
maximum=1
Displayed(tab/group)=Binding SID

bindingSidOperAddress Indicates the operational value of the SRv6 binding SID.

type=InetAddress
access=read-only
Displayed(tab/group)=Operational Address

bindingSidOperAddressType Indicates the type of bindingSidOperAddress.

type=rtr.InetAddressType
access=read-only
Displayed(tab/group)=Operational Address Type

locatorFunction Specifies the function for the locator specified by the value of LocatorName. The LocatorFunction can be set to a not default value only when LocatorName is set to a not default value.

type=rtr.BindingSidLocatorFunctionType
default=none
Displayed(tab/group)=Function (/Locator)

locatorFunctionOperErrorCode Indicates the error code for the function.

type=rtr.LocatorFunctionErrorCodeType
access=read-only
Displayed(tab/group)=Operational Function Error Code (/Locator)

locatorFunctionValue Specifies the function value for the locator specified by the value of LocatorName. If the value is not specified (set to the default) it will be dynamically assigned by the system. The value of LocatorFunctionValue can be not default only when the value of LocatorFunction and LocatorName is not default

type=long
default=0
minimum=0
maximum=1048575
Displayed(tab/group)=Function Value (/Locator)

locatorName Specifies the locator for the static policy. The value of LocatorName must be not default when the head-end of the policy is the local node. Binding SID address and locator can't be both configured at the same time.

type=string
default=
Displayed(tab/group)=Name (/Locator)

locatorOperFunctionValue Indicates the operational value of the locator function, for locator specified by the value of LocatorName. If the value is equal to 0 it means there is no function value allocated for this locator.

type=long
access=read-only
Displayed(tab/group)=Operational Function Value (/Locator)

policyName Specifies the name for the segment routing static policy.

type=string
access=read-only

routerId

type=int
access=read-only
default=1
minimum=1
maximum=10240

siteId

type=string
access=read-only
default=0.0.0.0
maximum=64
Displayed(tab/group)=Site ID (/Site)

  
Properties inherited from ManagedObject
actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed
 
Supported Network Elements
7450 ESS Supported from 22.7.R1
7750 SR Supported from 22.7.R1
7705 SAR Gen 2
7950 XRS Supported from 22.7.R1