ethernettunnel
CcTestEthernetPath

The CcTestEthernetPath object defines an Ethernet Path to be used in the CFM test. The creation of this object will result in the creation of MEPs on the two Ethernet Tunnel Path Endpoints belonging to the Ethernet Path.



public class CcTestEthernetPath

Properties
ethPathPointer The Ethernet Path selected for this CC Test.

type=Pointer
access=read-create
default=
Mandatory on create
Displayed(tab/group)=Ethernet Tunnel Path

ethRingPathPointer The Ethernet Ring Path selected for this CC Test.

type=Pointer
access=read-create
default=
Mandatory on create
Displayed(tab/group)=Ethernet Ring Path

id The identifier for the CcTestEthernetPath.

type=long
access=read-create
default=0
minimum=1
maximum=2147483647
Displayed(tab/group)=Object ID

runCcProtocol Specifies that the Continuity Check Protocol will be run on the Ethernet Path. If set to 'true', Remote MEPs will be synchronized between the Ethernet Path's endpoints and the created MEPs will have the 'administrativeState' property set to 'Up' and the 'ccEnable' property set to 'true'.

type=boolean
access=read-create
default=true
Displayed(tab/group)=Run Continuity Check Protocol

setControlMep If set to 'true', the created MEPs will have the 'controlMep' property set to 'true'.

type=boolean
access=read-create
default=true
Displayed(tab/group)=Set Control MEP property on created MEPs

  
Properties inherited from ManagedObject
actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed