ethernettunnel
AbstractPath

The AbstractPath class contains the common attributes for the EthernetPath and ethring.Path classes.



public abstract class AbstractPath

Properties
aggrPathEndptOperationalState

type=netw.OperationalState
access=read-only
Displayed(tab/group)=Aggregated Path Endpoint Operational State

autoCreateGlobalMeg Automatically create a Global MEG for this Path using the Maintenance Domain Pointer provided, this will then Create Maintenance Associations for each site and MEPs for each end point.

type=boolean
default=false
Displayed(tab/group)=Auto Create Global MEG (CFM Continuity Check/Global MEG Auto Creation)

autoRunCCM When the Global MEG is created, setting this property to 'true' will create Maintenance Entity Groups, MEPs and synchronize Remote MEPs on the two path endpoints. On the MEPs, the administrativeState property will be set to 'Up', controlMep property will be set to 'true' and ccEnable will be set to 'true'.

type=boolean
default=false
Displayed(tab/group)=Run CCM On Create (CFM Continuity Check/Global MEG Auto Creation)

ccProtocolState

type=ethernettunnel.CcProtocolStateEnum
access=read-only
default=ccTestNotRunning
Displayed(tab/group)=CC Protocol State (CFM Continuity Check)

ccTestPointer The CFM Test parameter specifies a pointer to an existing CC Test. This is the CC Test under which MEPs for the Ethernet tunnel path endpoints under the Ethernet tunnel path are created.

type=Pointer
default=
Displayed(tab/group)=CFM Test (CFM Continuity Check)

ccmInterval Specifies the ccm-interval to use on the Generated MEGs.

type=ethernettunnel.CCMInterval
default=CCM100ms
Displayed(tab/group)=CCM Interval (CFM Continuity Check/Global MEG Auto Creation)

createMepsOnSelection When the ccTestPointer is modified, setting this property to 'true' will create Maintenance Entity Groups and MEPs. On the MEPs, the administrativeState property will be set to 'Up', controlMep property will be set to 'true' and ccEnable will be set to 'true'.

type=boolean
default=false
Displayed(tab/group)=Create MEPs (CFM Continuity Check/Mep Auto Creation)

description

type=string
default=
minimum=0
maximum=80
Displayed(tab/group)=Description

endpointAAdministrativeState

type=netw.AdministrativeState
default=tmnxInService
Displayed(tab/group)=Administrative State (Endpoints/Endpoint A )

endpointACtpPointer The Member Port parameter associates a port with Ethernet Tunnel Path Endpoint A. After the parameter is set, the member port cannot be modified.

type=Pointer
default=
Displayed(tab/group)=Member Port (Endpoints/Endpoint A )

endpointASiteId

type=string
access=read-only
default=0.0.0.0
maximum=50
Displayed(tab/group)=Site ID (Endpoints/Endpoint A )

endpointBAdministrativeState

type=netw.AdministrativeState
default=tmnxInService
Displayed(tab/group)=Administrative State (Endpoints/Endpoint B )

endpointBCtpPointer The Member Port parameter associates a port with Ethernet Tunnel Path Endpoint B. After the parameter is set, the member port cannot be modified.

type=Pointer
default=
Displayed(tab/group)=Member Port (Endpoints/Endpoint B )

endpointBSiteId

type=string
access=read-only
default=0.0.0.0
maximum=50
Displayed(tab/group)=Site ID (Endpoints/Endpoint B )

id

type=int
access=read-create
default=0
Displayed(tab/group)=ID

maintDomainPointer The pointer to the Maintenance Domain.

type=Pointer
default=
Displayed(tab/group)=Maintenance Domain (CFM Continuity Check/Global MEG Auto Creation)

operationalFlags Specifies the conditions that affect the operating status of this Ethernet Path.

type=ethernettunnel.PathOperFlags
access=read-only
Displayed(tab/group)=Operational Flags

pathEndpointAMepPointer

type=Pointer
access=read-only
default=
Displayed(tab/group)=Endpoint A MEP (CFM Continuity Check/MEPs)

pathEndpointAPointer The Path Endpoint parameter specifies a pointer to an existing Ethernet tunnel path endpoint. This parameter should be set if you add an existing Ethernet tunnel path endpoint to an Ethernet tunnel path.

type=Pointer
default=

pathEndpointBMepPointer

type=Pointer
access=read-only
default=
Displayed(tab/group)=Endpoint B MEP (CFM Continuity Check/MEPs)

pathEndpointBPointer The Path Endpoint parameter specifies a pointer to an existing Ethernet tunnel path endpoint. This parameter should be set if you add an existing Ethernet tunnel path endpoint to an Ethernet tunnel path.

type=Pointer
default=

runCCOnSelection When the ccTestPointer is modified, setting this property to 'true' will create Maintenance Entity Groups, MEPs and synchronize Remote MEPs on the two path endpoints. On the MEPs, the administrativeState property will be set to 'Up', controlMep property will be set to 'true' and ccEnable will be set to 'true'.

type=boolean
default=false
Displayed(tab/group)=Run Continuity Check Protocol (CFM Continuity Check/Mep Auto Creation)

  
Properties inherited from ManagedObject
actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed