| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| mode |
The value of mode specifies how the system behaves during power contention.
type=equipment.PowerManagementMode default=basic Displayed(tab/group)=Management Mode |
| overload |
The value specifies whether or not the SROS will trigger an alarm when the required power capacity of the zone
exceeds the actual power capacity and no cards other than those deemed essential are available for shutdown.
type=boolean default=false |
| safetyAlert |
The value specifies the power capacity threshold where the SROS will trigger an event indicating a potential
trigger of the safety-level state.
type=long default=0 minimum=0 maximum=105600 units=Watts Displayed(tab/group)=Power Safety Alert |
| safetyLevel |
The value specifies the percentage of the provisioned power requirement that will cause the system to start
powering off lower-priority cards.
type=int default=100 minimum=0 maximum=100 units=% Displayed(tab/group)=Power Safety Level |
| siteId |
type=string access=read-only default= maximum=64 Displayed(tab/group)=Site ID (/Site) |
| siteName |
type=string access=read-only default= maximum=252 Displayed(tab/group)=Site Name (/Site) |
| zoneId |
The value specifies the managed power-zone for this management entity.
type=int access=read-create default=1 Displayed(tab/group)=Management Zone |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |
| Supported Network Elements | |
|---|---|
| 7950 XRS | Supported from 11.0.R7 |
| 7750 SR |
Supported from 16.0.R1
|
| 7705 SAR Gen 2 | |
| 7250 IXR |
Supported from 13.1.R4
|