Properties |
|
currentAmperagePeriodicThreshold |
Indicates the current drawn by the managed hardware component in milli-Amperes (mA).
type=long
access=read-only default=0 units=mA
|
|
currentAmperagePeriodicThresholdEnabled |
type=boolean
access=read-only default=false units=mA
|
|
currentVoltagePeriodicThreshold |
Indicates the current voltage use of the managed hardware component in milli-Volts (mV).
type=long
access=read-only default=0 units=mV
|
|
currentVoltagePeriodicThresholdEnabled |
type=boolean
access=read-only default=false units=mV
|
|
currentWattagePeriodicThreshold |
Indicates the current power use of the managed hardware component in milli-Watts (mW).
type=long
access=read-only default=0 units=mW
|
|
currentWattagePeriodicThresholdEnabled |
type=boolean
access=read-only default=false units=mW
|
|
minAmperagePeriodicThreshold |
Indicates the lowest current drawn by the managed hardware component in milli-Amperes (mA) last
recorded at the time indicated by MinAmperageTime.
type=long
access=read-only default=0 units=mA
|
|
minAmperagePeriodicThresholdEnabled |
type=boolean
access=read-only default=false units=mA
|
|
minVoltagePeriodicThreshold |
Indicates the lowest voltage use of the managed hardware component in milli-Volts (mV) last
recorded at the time indicated by MinVoltageTime.
type=long
access=read-only default=0 units=mV
|
|
minVoltagePeriodicThresholdEnabled |
type=boolean
access=read-only default=false units=mV
|
|
minWattagePeriodicThreshold |
Indicates the lowest power use of the managed hardware component in milli-Watts (mW) last
recorded at the time indicated by MinWattageTime.
type=long
access=read-only default=0 units=mW
|
|
minWattagePeriodicThresholdEnabled |
type=boolean
access=read-only default=false units=mW
|
|
peakAmperagePeriodicThreshold |
Indicates the peak current drawn by the managed hardware component in milli-Amperes (mA) last
recorded at the time indicated by PeakAmperageTime.
type=long
access=read-only default=0 units=mA
|
|
peakAmperagePeriodicThresholdEnabled |
type=boolean
access=read-only default=false units=mA
|
|
peakVoltagePeriodicThreshold |
Indicates the peak voltage use of the managed hardware component in milli-Volts (mV) last
recorded at the time indicated by PeakVoltageTime.
type=long
access=read-only default=0 units=mV
|
|
peakVoltagePeriodicThresholdEnabled |
type=boolean
access=read-only default=false units=mV
|
|
peakWattagePeriodicThreshold |
Indicates the peak power use of the managed hardware component in milli-Watts (mW) last
recorded at the time indicated by PeakWattageTime.
type=long
access=read-only default=0 units=mW
|
|
peakWattagePeriodicThresholdEnabled |
type=boolean
access=read-only default=false units=mW
|