equipment
AuxAlarmDefinition



public class AuxAlarmDefinition

Properties
adminState

type=equipment.AlarmAdminState
default=disabled
Displayed(tab/group)=Administrative State

analogOperation Selects whether analog inputs become active when the detected voltage is greater than or less than the configured threshold.

type=equipment.AnalogOperation
default=notMonitored
Displayed(tab/group)=Operation (Inputs)

analogThreshold Analog input voltage threshold for all analog inputs associated with this alarm.

type=int
default=0
minimum=0
maximum=75000
units=mV
Displayed(tab/group)=Analog Threshold (Inputs)

chassisRelays Selects whether alarm causes chassis LEDs and relays to be updated.

type=boolean
default=true
Displayed(tab/group)=Update Chassis Relays (Outputs)

description

type=string
default=
minimum=0
maximum=160
Displayed(tab/group)=Description

detectedInputs Bit mask of currently detected inputs. The bitmask is based on the trigger index assigned.

type=equipment.DetectedInputBitmask
access=read-only
default=0
Displayed(tab/group)=Detected Inputs

id

type=int
access=read-create
default=0
minimum=1
maximum=2147483647
Displayed(tab/group)=ID

inputEight

type=Pointer
default=
Displayed(tab/group)=Input 8 (Inputs)

inputEightId

type=long
access=read-only

inputFive

type=Pointer
default=
Displayed(tab/group)=Input 5 (Inputs)

inputFiveId

type=long
access=read-only

inputFour

type=Pointer
default=
Displayed(tab/group)=Input 4 (Inputs)

inputFourId

type=long
access=read-only

inputOne

type=Pointer
default=
Displayed(tab/group)=Input 1 (Inputs)

inputOneId

type=long
access=read-only

inputSeven

type=Pointer
default=
Displayed(tab/group)=Input 7 (Inputs)

inputSevenId

type=long
access=read-only

inputSix

type=Pointer
default=
Displayed(tab/group)=Input 6 (Inputs)

inputSixId

type=long
access=read-only

inputThree

type=Pointer
default=
Displayed(tab/group)=Input 3 (Inputs)

inputThreeId

type=long
access=read-only

inputTwo

type=Pointer
default=
Displayed(tab/group)=Input 2 (Inputs)

inputTwoId

type=long
access=read-only

logEvent Selects whether alarm causes a log event to be generated.

type=boolean
default=true
Displayed(tab/group)=Log Event (Outputs)

operState

type=equipment.AlarmOperState
access=read-only
default=unknown
Displayed(tab/group)=Operational State

severity Severity of the alarm to be raised.

type=equipment.AuxAlarmSeverity
default=major
Displayed(tab/group)=Severity

shelfId

type=int
access=read-only
default=0

siteId

type=string
access=read-only
default=

templateVersionPointer Pointer to the template if this object was created from a template.

type=Pointer
default=
Displayed(tab/group)=Associated Template (Template/Associated Template)

triggerRule Selects whether alarm is triggered on any input becoming active (ie logical OR) or on all inputs becoming active (ie logical AND).

type=equipment.TriggerRule
default=any
Displayed(tab/group)=Trigger Rule (Inputs)

  
Properties inherited from ManagedObject
actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed
 
Supported Network Elements
7705 SAR H
7705 SAR Supported from 3.0.R3