| Overview | Package | Class | Deprecated | Help |
| Properties | |
|---|---|
| adminState |
type=equipment.AlarmAdminState default=disabled Displayed(tab/group)=Administrative State |
| analogOperation |
Selects whether analog inputs become active when the detected voltage is
greater than or less than the configured threshold.
type=equipment.AnalogOperation default=notMonitored Displayed(tab/group)=Operation (Inputs) |
| analogThreshold |
Analog input voltage threshold for all analog inputs associated with this alarm.
type=int default=0 minimum=0 maximum=75000 units=mV Displayed(tab/group)=Analog Threshold (Inputs) |
| chassisRelays |
Selects whether alarm causes chassis LEDs and relays to be updated.
type=boolean default=true Displayed(tab/group)=Update Chassis Relays (Outputs) |
| description |
type=string default= minimum=0 maximum=160 Displayed(tab/group)=Description |
| detectedInputs |
Bit mask of currently detected inputs. The bitmask is
based on the trigger index assigned.
type=equipment.DetectedInputBitmask access=read-only default=0 Displayed(tab/group)=Detected Inputs |
| id |
type=int access=read-create default=0 minimum=1 maximum=2147483647 Displayed(tab/group)=ID |
| inputEight |
type=Pointer default= Displayed(tab/group)=Input 8 (Inputs) |
| inputEightId |
type=long access=read-only |
| inputFive |
type=Pointer default= Displayed(tab/group)=Input 5 (Inputs) |
| inputFiveId |
type=long access=read-only |
| inputFour |
type=Pointer default= Displayed(tab/group)=Input 4 (Inputs) |
| inputFourId |
type=long access=read-only |
| inputOne |
type=Pointer default= Displayed(tab/group)=Input 1 (Inputs) |
| inputOneId |
type=long access=read-only |
| inputSeven |
type=Pointer default= Displayed(tab/group)=Input 7 (Inputs) |
| inputSevenId |
type=long access=read-only |
| inputSix |
type=Pointer default= Displayed(tab/group)=Input 6 (Inputs) |
| inputSixId |
type=long access=read-only |
| inputThree |
type=Pointer default= Displayed(tab/group)=Input 3 (Inputs) |
| inputThreeId |
type=long access=read-only |
| inputTwo |
type=Pointer default= Displayed(tab/group)=Input 2 (Inputs) |
| inputTwoId |
type=long access=read-only |
| logEvent |
Selects whether alarm causes a log event to be generated.
type=boolean default=true Displayed(tab/group)=Log Event (Outputs) |
| operState |
type=equipment.AlarmOperState access=read-only default=unknown Displayed(tab/group)=Operational State |
| severity |
Severity of the alarm to be raised.
type=equipment.AuxAlarmSeverity default=major Displayed(tab/group)=Severity |
| shelfId |
type=int access=read-only default=0 |
| siteId |
type=string access=read-only default= |
| templateVersionPointer |
Pointer to the template if this object was created from a template.
type=Pointer default= Displayed(tab/group)=Associated Template (Template/Associated Template) |
| triggerRule |
Selects whether alarm is triggered on any input becoming active (ie logical OR)
or on all inputs becoming active (ie logical AND).
type=equipment.TriggerRule default=any Displayed(tab/group)=Trigger Rule (Inputs) |
| Properties inherited from ManagedObject |
|---|
| actionMask, children-Set, deploymentState, isFaultSquelched, name, objectFullName, selfAlarmed |
| Supported Network Elements | |
|---|---|
| 7705 SAR H | |